IMO iDrive2 XKL Instruction Manual page 39

General application inverter
Table of Contents

Advertisement

iDrive2 inverters
Function
Name
code
limit of AI1
AI1 input
P05.36
filter time
Lower limit of
P05.37
AI2
Correspondi
ng setting of
P05.38
the lower
limit of AI2
Upper limit of
P05.39
AI2
Correspondi
ng setting of
P05.40
the upper
limit of AI2
AI2 input
P05.41
filter time
Y1 output
P06.01
selection
Relay RO
P06.03
output
Detailed instruction of parameters
Input filter time: this parameter is used to adjust the
sensitivity of the analog input. Increasing the value
properly can enhance the anti-interference of the analog,
but weaken the sensitivity of the analog input.
Note: AI2 can support 0~10V or 0~20mA input, when
AI2 selects 0~20mA input, the corresponding voltage of
20mA is 5V. AI3 can support the output of -10V~+10V.
The setting range of P05.32:0.00V~P05.34
The setting range of P05.33:-100.0%~100.0%
The setting range of P05.34:P05.32~10.00V
The setting range of P05.35:-100.0%~100.0%
The setting range of P05.36:0.000s~10.000s
The setting range of P05.37:0.00V~P05.39
The setting range of P05.38:-100.0%~100.0%
The setting range of P05.39:P05.37~10.00V
The setting range of P05.40:-100.0%~100.0%
The setting range of P05.41:0.000s~10.000s
P06 Group
Output terminals
0:Invalid
1:On operation
2:Forward rotation operation
3:Reverse rotation operation
4: Jogging operation
5:The inverter fault
6:Frequency detection FDT1
7:Frequency detection FDT2
8:Frequency arrival
9:Zero speed running
10:Upper limit frequency arrival
11:Lower limit frequency arrival
39
Function Parameters
Default
Modify
value
0.100s
0.00V
0.0%
10.00V
100.0%
0.100s
0
1