IMO iDrive2 XKL Instruction Manual page 38

General application inverter
Table of Contents

Advertisement

iDrive2 inverters
Function
Name
code
S2
terminal
P05.17
switching off
delay time
S3 terminal
P05.18
switching on
delay time
S3
terminal
P05.19
switching off
delay time
S4 terminal
P05.20
switching on
delay time
S4
terminal
P05.21
switching off
delay time
S5 terminal
P05.22
switching on
delay time
S5 terminal
P05.23
switching off
delay time
Lower limit of
P05.32
AI1
Correspondi
ng setting of
P05.33
the lower
limit of AI1
Upper limit of
P05.34
AI1
Correspondi
P05.35
ng setting of
the upper
Detailed instruction of parameters
The function code defines the relationship between the
analog input voltage and its corresponding set value. If
the analog input voltage beyond the set minimum or
maximum input value, the inverter will count at the
minimum or maximum one.
When the analog input is the current input, the
corresponding voltage of 0~20mA is 0~10V.
In different cases, the corresponding rated value of
100.0% is different. See the application for detailed
information.
The figure below illustrates different applications:
38
Function Parameters
Default
Modify
value
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0.000s
0.00V
0.0%
10.00V
100.0%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents