IMO iDrive2 XKL Instruction Manual page 25

General application inverter
Table of Contents

Advertisement

iDrive2 inverters
Function
Name
code
setting
source
Keypad set
P00.10
frequency
P00.11
ACC time 1
P00.12
DEC time 1
Running
P00.13
direction
selection
Detailed instruction of parameters
1: B, the current frequency setting is B frequency
command
2: A+B, the current frequency setting is sum of A+B
frequency command.
3: A-B, the current frequency setting is A frequency
command - B frequency command
4: Max (A, B): The highest value of A and B is the set
frequency.
5: Min (A, B): The lowest value of A and B is the set
frequency.
Note:The combination manner can be shifted by
P05(terminal function).
When A and B frequency commands are selected as
"keypad setting", this parameter will be the initial value of
inverter reference frequency
Setting range:0.00 Hz~P00.03(the Max. frequency)
Time (secs) to ramp up to Max frequency (P00.03) from
0Hz.
Time (secs) to ramp down from Max frequency (P00.03)
to 0Hz.
IMO XKL series inverters define four groups of
ACC/DEC time which can be selected by P05. The
factory default ACC/DEC time of the inverter is the first
group.
Setting range of P00.11 and P00.12:0.0~3600.0s
0: Runs at the default direction, the inverter runs in the
forward direction. FWD/REV indicator is off.
1: Runs at the opposite direction, the inverter runs in the
reverse direction. FWD/REV indicator is on.
Modify the function code to shift the rotation direction of
the motor. The motor rotation direction can be changed
by QUICK/JOG on the keypad. Refer to parameter
P07.02.
Note: Factory reset returns motor direction to default,
check direction of motor is correct before running after
reset.
2: Forward run only: Prevents motor running in reverse
direction.
25
Function Parameters
Default
Modify
value
50.00Hz
Depend
on model
Depend
on model
0