IMO iDrive2 XKL Instruction Manual page 50

General application inverter
Table of Contents

Advertisement

iDrive2 inverters
Function
Name
code
Setting
P08.27
running time
Time of fault
P08.28
reset
Interval time
P08.29
of automatic
fault reset
FDT
electrical
P08.32
level
detection
value
FDT
retention
P08.33
detection
value
Frequency
P08.36
arrival
Detailed instruction of parameters
Setting range of P08.25:P08.26~65535
Setting range of P08.26:0~P08.25
Pre-set running time of the inverter. When the
accumulative running time reaches the set time, the
multi-function digital output terminals will output the
signal of "running time arrival".
Setting range:0~65535min
The time of the fault reset: The fault reset time can be
set by this function. If the reset time exceeds this set
value, the inverter will stop for the fault and wait to be
repaired.
The interval time of the fault reset: The interval between
the time when the fault occurs and the time when the
reset action occurs.
Setting range of P08.28:0~10
Setting range of P08.29:0.1~3600.0s
When the output frequency exceeds the corresponding
frequency of FDT level, the multi-function digital output
terminals will output the signal of "frequency level detect
FDT" until the output frequency decreases to a value
lower
than
(FDT
electrical
detection value) the corresponding frequency, the signal
is invalid. Below is the waveform diagram:
Setting range of P08.32: 0.00Hz~P00.03(the Max.
frequency)
Setting range of P08.33: 0.0~100.0%(FDT electrical
level)
When the output frequency is below or above the range
of the set frequency, the multi-function digital output
50
level—FDT
retention
Function Parameters
Default
Modify
value
0m
0
1.0s
50.00Hz
5.0%
0.00Hz