IMO iDrive2 XKL Instruction Manual page 9

General application inverter
Table of Contents

Advertisement

iDrive2 inverters
Function
Temperature of the running
Others
resolution
Terminal analog input
resolution
Analog input
Analog output
Digital input
Digital output
Communication
Frequency setting
Automatic voltage
adjustment
Fault protection
Mountable method
environment
Cooling
Enclosure
Braking unit
DC reactor
Braking resistor
Optional EMC filters
Specification
≤ 20mV
1 input 0~10V/0~20mA
1 input 0~10V/0~20mA
5 common input
1 Y output (commonly used with digital output) and 1
programmable relay output
485 communication
Digital setting, analog setting, multi-step speed setting, PID
setting, MODBUS communication setting and so on
Switch between different settings
Keeps output voltage stable when the grid voltage changes
More than 10 fault protections
Wall mountable
-10~50℃, derate above 40℃
Single/three-phase 230V 0.2-0.75kW natural cooling
Single/three-phase 230V 1.5-2.2kW, three-phase 380V
0.75-2.2kW
IP20
Embedded
Not optional
Optional and external
C2 or C3 filter options
9
Product overview

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents