iDrive2 inverters
Function
Name
code
Multi-stage
P10.02
speed 0
Multi-stage
P10.04
speed 1
Multi-stage
P10.06
speed 2
Multi-stage
P10.08
speed 3
Multi-stage
P10.10
speed 4
Multi-stage
P10.12
speed 5
Multi-stage
P10.14
speed 6
Multi-stage
P10.16
speed 7
Multi-stage
P10.18
speed 8
Multi-stage
P10.20
speed 9
Multi-stage
P10.22
speed 10
Multi-stage
P10.24
speed 11
Multi-stage
P10.26
speed 12
Detailed instruction of parameters
quickly.
LED tens:
0: The same with the setting direction; if the output of
PID adjustment is different from the current running
direction, the internal will output 0 forcedly.
1:Opposite to the setting direction
P10 Group
Simple PLC and multi-stage speed control
100.0% of the frequency setting corresponds to the Max.
Frequency P00.03.
When selecting simple PLC running, set P10.02~P10.33
to define the running frequency and direction of all
stages.
Note: The symbol of multi-stage determines the running
direction of simple PLC. The negative value means
reverse rotation.
Multi-stage speeds are in the range of --f
can be
IMO XKL series inverters can set 16 stages speed,
selected by the combination of multi-stage terminals
1~4, corresponding to the speed 0 to speed 15.
When
S1=S2=S3=S4=OFF,
reference is selected via P00.06 or P00.07. When all
S1=S2=S3=S4 terminals aren't off, it runs at multi-stage
which takes precedence of keypad, analog value,
high-speed pulse, PLC, communication frequency input.
~f
max
max
the
frequency
57
Function Parameters
Default
Modify
value
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
and it
0.0%
0.0%
0.0%
0.0%
0.0%
input
0.0%
0.0%