iDrive2 inverters
Function
Name
code
Virtual
P05.12
terminals
setting
Terminals
control
P05.13
running
mode
S1 terminal
P05.14
switching on
delay time
S1
terminal
P05.15
switching off
delay time
S2 terminal
P05.16
switching on
delay time
Detailed instruction of parameters
Enable the input function of virtual terminals at the
communication mode.
0:Virtual terminals is invalid
1:MODBUS communication virtual terminals are valid
Set the operation mode of the terminals control
0:2-wire control 1, comply the enable with the direction.
This mode is widely used. It determines the rotation
direction by the defined FWD and REV terminals
command.
1:2-wire control 2;Separate the enable from the
direction. FWD defined by this mode is the enabling
ones. The direction depends on the state of the defined
REV.
2:3-wire control 1; Sin is the enabling terminal in this
mode, and the running command is caused by FWD and
the direction is controlled by REV. Sin is natural closed.
3:3-wire control 2; Sin is the enabling terminal on this
mode, if set Si (i=1~5) to 3, when K is switched on, the
control of FWD and REV is valid; when K is switched off,
the control of FWD and REV is invalid. The inverter
stops.
Note: for the 2-wire running mode, when FWD/REV
terminal is valid, the inverter stop because of the
stopping command from other sources, even the control
terminal FWD/REV keeps valid; the inverter won't work
when the stopping command is canceled. Only when
FWD/REV is relaunched, the inverter can start again.
The function code defines the corresponding delay time
of electrical level of the programmable terminals from
switching on to switching off.
Setting range:0.000~50.000s
37
Function Parameters
Default
Modify
value
0
0
0.000s
0.000s
0.000s