Descriptive Error; Flow Control - Christie Crimson Technical Reference

Table of Contents

Advertisement

Descriptive error

The following error codes indicate a problem if a command cannot be performed.
Error code
Description
3
Invalid parameter
4
Too many parameters
5
Too few parameters
6
Channel not found
7
Command not executed
8
Checksum error
9
Unknown request
10
Error receiving serial data
101
Control not found
102
Subcontrol not found
103
Wrong control type
104
Invalid value

Flow control

Normally messages can be sent to the projector before processing of earlier messages is complete—
Crimson stores messages in a buffer until ready to process. However, if a series of messages is sent,
Crimson may not be able to process them as fast as they arrive and the buffer becomes full.
If this happens, Crimson sends the 13h (Xoff) code to instruct the controller (or any devices preparing
to transmit) to cease transmission. At this point, the controller must respond immediately and send no
more than 10 extra characters or they may be lost (such as, Crimson can accommodate the receipt of
up to 10 more bytes after it sends 13h (Xoff)). When the buffer is once again available, Crimson sends
a 11h (Xon) command to resume transmission.
Xon and Xoff controls apply to both directions of communication. Crimson does not send more than
three characters after it has received a 13h (Xoff) code.
Crimson and Crimson Mirage Technical Reference–Serial Commands
020-102660-01 Rev. 1 (07-2018)
Copyright
2018 Christie Digital Systems USA, Inc. All rights reserved.
©
Communicating with Crimson
Error code
Description
105
Disabled control
106
Invalid language
107
Exceeded list size
110
Communication timeout
111
Communications failure
112
Failed to set hardware
113
Bad file
114
Memory failure
115
Not implemented
116
Invalid security
117
Invalid access group
118
System busy - Try again later
12