Fcs-Lens Focus Position Adjustment - Christie Crimson Technical Reference

Table of Contents

Advertisement

(EVT 2)
Result:
(EVT!002 "2013-03-17 04:01:13.855" "Error" "(SST+TEMP?002) Air Intake Temperature
(Temp 2) = Communication fault (shutdown)")
(EVT!000 "2013-03-17 04:47:18.340" "OK" "Setting Time to 06:47:17")
(EVT!"--END--")
Retrieve all events from a specific point in time until now:
(EVT "2013-03-17 04:01:13")
Result:
(EVT!000 "2013-03-17 04:47:18.340" "OK" "Setting Time to 06:47:17")
(EVT!002 "2013-03-17 04:01:13.855" "Error" "(SST+TEMP?002) Air Intake Temperature
(Temp 2) = Communication fault (shutdown)")
(EVT!003 "2013-03-17 04:01:13.824" "Error" "(SST+TEMP?000) Integrator Rod Temperature
(Temp 1) = Communication fault (shutdown)")
(EVT!"--END--")
Retrieve all events between two specific points in time:
(EVT "2013-03-17 04:01:08" "2013-03-17 04:01:12")
Result:
(EVT!004 "2013-03-17 04:01:12.663" "Error" "(SST+TEMP?000) Integrator Rod Temperature
(Temp 1) = Communication fault (shutdown)")
(EVT!"--END--")
FCS–Lens Focus Position Adjustment
Sets the lens focus to an absolute position.
Commands
Command
Description
FCS?m
Returns the minimum/maximum range of the zoom axis based on
the last lens calibration performed. The returned range is persistent
across AC cycles. (Read-only)
FCS <position> Adjusts the lens focus to the specified position.
Examples
Move lens focus to position 500:
(FCS 500)
Crimson and Crimson Mirage Technical Reference–Serial Commands
020-102660-01 Rev. 1 (07-2018)
Copyright
2018 Christie Digital Systems USA, Inc. All rights reserved.
©
Serial API commands
Values
position = A numeric value
subject to the range
returned in FCS?m
27