Evt-Event Manager - Christie Crimson Technical Reference

Table of Contents

Advertisement

Command
Description
EVT–Event Manager
Retrieves a list of log messages for the current AC cycle from the projector.
Commands
Command
Description
EVT
Returns all events starting from the most
recent event on the projector back to AC
start. (Read-only)
EVT <max>
Returns a set number of events starting
from the most recent event on the projector
going back to AC start. (Read-only)
EVT <start
Returns all events from <start timestamp>
timestamp>
back to current time. (Read-only)
EVT <start
Returns all events between two specific
timestamp> <end
timestamps. (Read-only)
timestamp>
Examples
Retrieve all events since last AC start:
(EVT)
Result:
(EVT!000 "2013-03-17 04:47:18.340" "OK" "Setting Time to 06:47:17")
(EVT!002 "2013-03-17 04:01:13.855" "Error" "(SST+TEMP?002) Air Intake Temperature
(Temp 2) = Communication fault (shutdown)")
(EVT!003 "2013-03-17 04:01:13.824" "Error" "(SST+TEMP?000) Integrator Rod Temperature
(Temp 1) = Communication fault (shutdown)")
(EVT!"--END--")
Retrieve two most recent events:
Crimson and Crimson Mirage Technical Reference–Serial Commands
020-102660-01 Rev. 1 (07-2018)
Copyright
2018 Christie Digital Systems USA, Inc. All rights reserved.
©
Serial API commands
Values
246 = Yellow
247 = Diagonal Lines
248 = Dark Segmented Ramp
249 = Bright Segmented Ramp
255 = Off
Values
max = Maximum number of events to
return
start timestamp = String in the following
format:
yyyy = mm-dd hh:mm:ss
start timestamp = String in the following
format:
yyyy = mm-dd hh:mm:ss
end timestamp = String in the following
format:
yyyy = mm-dd hh:mm:ss
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crimson mirage

Table of Contents