Command
Description
LCB+LOCK <value>
Locks all lens motors preventing the lens from moving.
This overrides all other lens functions.
LCB+ZOMR <value>
Programs the lens connector board lens (LCBL) to
indicate that the lens is motorized or non-motorized.
LCB+ZOOM 1
Calibrates the zoom motor.
Examples
Start calibration:
(LCB 1)
Move the lens back to the home position:
(LCB+HOME)
LHO–Lens Horizontal Position Adjustment
Sets the lens horizontal location to an absolute position.
This command is only available when the projector is on.
Commands
Command
Description
LHO?m
Returns the minimum and maximum range of the zoom axis
based on the last lens calibration performed. The returned
range is persistent across AC cycles. (Read-only)
LHO
Adjusts the horizontal location of the lens to the specified
<position>
position. The position is persistent across AC cycles.
Examples
Move the lens to position 500 on the horizontal axis:
(LHO 500)
LMV–Lens Move
Adjusts all aspects of the lens position using a single command.
It can also be used to move the lens to a relative position or to start and stop the motors arbitrarily.
This command is only enabled when the projector is on.
Crimson and Crimson Mirage Technical Reference–Serial Commands
020-102660-01 Rev. 1 (07-2018)
Copyright
2018 Christie Digital Systems USA, Inc. All rights reserved.
©
Serial API commands
Values
0 = Unlocks motors (Default)
1 = Locks motors
0 = Lens does not have a zoom
(Default)
1 = Lens has a zoom motor
1
Values
position = Numeric value subject
to the range returned in LHO?m