Product Overview

4 Product Overview
4.1 VLT® High-power Drives
The Danfoss VLT
®
Each VLT
drive is configurable, compatible, and efficiency-optimized for all standard motor types, which avoids the
restrictions of motor-drive package deals. These drives come in 2 front-end configurations: 6-pulse and 12-pulse.
4
4
Benefits of VLT
Available in various enclosure sizes and protection ratings.
98% efficiency reduces operating costs.
Unique back-channel cooling design reduces the need for more cooling equipment, resulting in lower installation
and recurring costs.
Lower power consumption for control room cooling equipment.
Reduced ownership costs.
Consistent user interface across the entire range of Danfoss drives.
Application-oriented start-up wizards.
Multi-language user interface.
Benefits of VLT
®
The VLT
12-pulse is a high efficiency AC drive that provides harmonic reduction without adding capacitive or inductive
components, which often require network analysis to avoid potential system resonance problems. The 12-pulse is built with
the same modular design as the popular 6-pulse VLT
Harmonic Filter AHF 005/AHF 010 Design Guide.
The 12-pulse drives provide the same benefits as the 6-pulse drives in addition to being:
Robust and highly stable in all network and operating conditions.
Ideal for applications where stepping down from medium voltage is required or where isolation from the grid is
needed.
Excellent input transient immunity.

4.2 Enclosure Size by Power Rating

kW
1)
Hp
1)
315
450
355
500
400
550
450
600
500
650
560
750
630
900
710
1000
800
1200
1000
1350
Table 4.1 Enclosure Power Ratings, 380–480 V
1) All power ratings are taken at normal overload.
Output is measured at 400 V (kW) and 460 V (hp).
12
VLT
®
drives described in this manual are available as free-standing, wall-mounted, or cabinet-mounted units.
®
6-pulse drives
®
12-pulse drives
Available enclosures
6-pulse
E1–E2
E1–E2
E1–E2
F1–F3
F1–F3
F1–F3
F1–F3
F2–F4
F2–F4
Danfoss A/S © 11/2017 All rights reserved.
®
HVAC Drive FC 102
®
drive. For more harmonic reduction methods, see the VLT
12-pulse
kW
1)
Hp
F8–F9
450
F8–F9
500
F8–F9
560
F8–F9
630
F10–F11
710
F10–F11
800
F10–F11
900
F10–F11
1000
F12–F13
1200
F12–F13
1400
Table 4.2 Enclosure Power Ratings, 525–690 V
1) All power ratings are taken at normal overload.
Output is measured at 690 V (kW) and 575 V (hp).
Available enclosures
1)
6-pulse
450
E1–E2
500
E1–E2
600
E1–E2
650
E1–E2
750
F1–F3
950
F1–F3
1050
F1–F3
1150
F2–F4
1350
F2–F4
1550
F2–F4
®
Advanced
12-pulse
F8–F9
F8–F9
F8–F9
F8–F9
F10–F11
F10–F11
F10–F11
F12–F13
F12–F13
F12–F13
MG16C302