Specifications
®
VLT
HVAC Drive FC 102
Normal overload
(Normal overload=110% current during 60 s)
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 550 V) [A]
Continuous (at 575 V) [A]
Continuous (at 690 V) [A]
Maximum number and size of cables per phase
2
- Motor [mm
(AWG)]
- Mains [mm
2
(AWG)] (F1)
2
- Mains [mm
(AWG)] (F3)
- Load share [mm
2
(AWG)]
2
- Brake [mm
(AWG)]
Maximum external mains fuses [A]
Estimated power loss at 600 V [W]
Estimated power loss at 690 V [W]
Maximum added losses for circuit breaker or disconnect and contactor
[W], (F3 only)
Maximum panel options losses [W]
3)
Efficiency
Output frequency [Hz]
Control card overtemperature trip [°C (°F)]
Table 7.8 Electrical Data for Enclosures F1/F3, Mains Supply 3x525–690 V AC
1) For fuse ratings, see chapter 10.5 Fuses and Circuit Breakers.
2) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-
efficiency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for
slots A and B each add only 4 W.
3) Measured using 5 m (16.5 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy
efficiency class, see chapter 10.12 Efficiency. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
MG16C302
Design Guide
1)
2), 3)
2), 3)
Danfoss A/S © 11/2017 All rights reserved.
P710
NO
560
750
710
F1/F3
763
839
730
803
727
727
872
735
704
704
8x150 (8x300 mcm)
8x150 (8x300 mcm)
8x240 (8x500 mcm)
8x240 (8x500 mcm)
8x456 (4x900 mcm)
8x456 (4x900 mcm)
4x120 (4x250 mcm)
4x120 (4x250 mcm)
4x185 (4x350 mcm)
4x185 (4x350 mcm)
1600
9500
9863
427
400
0.98
0–500
85 (185)
± 15% (tolerance relates to variety in voltage and cable conditions). These
P800
P900
NO
NO
670
750
950
1050
800
900
F1/F3
F1/F3
889
988
978
1087
850
945
935
1040
847
941
847
941
1016
1129
857
952
819
911
819
911
8x150 (8x300
mcm)
8x240 (8x500
mcm)
8x456 (4x900
mcm)
4x120 (4x250
mcm)
4x185 (4x350
mcm)
1600
1600
10872
12316
11304
12798
532
615
400
400
0.98
0.98
0–500
0–500
85 (185)
85 (185)
7
7
55