1. Remove 2 screws securing the right laser interface to base plate.
2. Disconnect Laser Interface including Laser Cluster from the TI Loop by removing 2 screws (TX20 mM50X45) and Dow Tail clamps
(no need to open fully).
3. Release two screws (TX20 m50X45) opening the Dow Tail clamps. This releases the TI loop from the Illumination Engine Front.
1
2
1
Image 22-20
Image 22-22
4. Lift up and out the complete right light path including the Phosphor wheel compartment which you now have to separate from
the light path
5. Turn the TI Loop upside down, open the lid of the phosphor wheel compartment
6. Remove the air guide to access screws below.
7. Release 3 screws securing phosphor wheel to access 2 new screws below.
8. Remove 3 screws (TX8
22.4 Rod Carrier Assy
The Rod Carrier Assembly is mounted inside the Illumination engine front and is a Dual Rod system which merges the light from the
two illumination paths into a single seamless feed. It is recommended that you remove Color wheel prior to removing the rod carrier
assembly.
1. Remove 3 screws (Tx08 M2.5x6) and lift off Illumination engine cover.
2. Remove 3 screws (Tx8 M25x10) securing rod assembly to Illumination engine Front.
3. Carefully lift out rod assembly holding hollow rod.
723–0016 F90 01/12/2017
3
3
2
Image 22-21
22. TI Loop
117