21. DMD, DMD Board, CLGA & DMD heatsink elements
21.8 Remove the Laser Interface
The Laser Interface must be replaced as a complete assembly in the unlikely event of ROD or diffusor damage.
•
Laser cluster must be removed prior to this operation.
•
Temp sensor and safety switch must be loosened before removing laser interface.
Take note of the spacer below the left laser interface.
1. Release two screws (TX20 m50X45) opening the Dow Tail clamps. This will release the laser interface form the TI loop (not
necessary to open fully).
2. Remove two screws securing the laser interface to the base plate (Tx20 M4x12)
Image 21-14
Image 21-15
108
723–0016 F90 01/12/2017