Image 20-18
Image 20-20
5. 5. Loosen , but do not unscrew fully, the two screws (Tx20 M50x45) and slide off the locking clamp and remove the old laser
cluster. It is recommended to hold the cluster with one hand while loosen and removing the locking clamp, to avoid that the
cluster falling to the bottom.
6. 6. Position the new laser cluster to the Laser Interface. Ensure that the cluster is properly in place. The cluster will "fall in" to a
track, and it will not be possible to rotate it vertically when it is in correct position. The line between the cluster and the interface
will be narrow and paralell. Tighten up the clamps on each side, and ensure correct position and fit also for the clamps.
Note: All clamp screws must be tighten with a 3,1Nm torque.
723–0016 F90 01/12/2017
Image 20-19
20. Scheduled operations