Converging Lens (Exit); Adjusting Mirror; Ti Loop Right - Barco F90 Service Manual

Hide thumbs Also See for F90:
Table of Contents

Advertisement

22. TI Loop

22.2.9.2 Converging Lens (Exit)

In order to access the exit lens, the TI loop must be separated from the illumination engine.
Ensure the TI loop cover is mounted before you release the TI Loop.
1. Release two screws (TX20 m50X45) holding the Dow Tail clamps. This releases the TI loop form the Illumination Engine Front.
2. Release 4 screws (Tx8 M2.5x6) holding the clip and lens.
Image 22-16

22.2.10 Adjusting Mirror

1. 2. Remove 2 screws (TX8 M2, 6x6).
2. 2. Pull clips in the direction of the red arrow using a sharp implement (e.g. tip of scalpel) and replace Mirror blue.
Image 22-18

22.3 TI Loop Right

You may need to use a screw driver or similar to gently bend loose the light path from the remaining optical
engine.
Most components inside TI Loop right are mounted following same procedure as documented for left loop.
Exceptions are documented in the following chapter.
116
Image 22-17
Image 22-19
723–0016 F90 01/12/2017