Relay Tube Assy; Pcb Clo (Constant Light Output) - Barco F90 Service Manual

Hide thumbs Also See for F90:
Table of Contents

Advertisement

23. Illumination Engine front
Remove Iris assembly
1. Remove 3 screws (TX8 M2.5x6) and carefully lift out Illumination Iris cover including IRIS assy.
2. Take note of cable routing of limit switch through groove in Illumination Iris cover, as illustrated (green) in picture below.
3. Release Iris assy from the cover
Image 23-3
Removing Iris assembly incl cover.

23.2 Relay Tube assy

1. Remove two screws (TX8 M2.5x6), the clips and carefully lift out assembly.
2. In order to place the lens in correct position when assembling the Relay tube, use trace in the clip to match grove in lens. Note!
See Optical adjustment chapter 10.2 for adjustment of relay tube lens after service.
Image 23-5

23.3 PCB CLO (Constant Light Output).

1. Remove Fan Optics.
2. Remove 4 screws (Tx10 M3x6) securing the PCB to the CLO holder (TX10 I min, 8 I EWI)
120
Image 23-4
Releasing iris assembly from the cover.
Image 23-6
723–0016 F90 01/12/2017