Module Slot Assignments; Distinguishing A Supervisory Module From An I/O Module - NETGEAR 8800 Series Hardware Installation Manual

Chassis switch
Table of Contents

Advertisement

8800 Series Chassis Switch Hardware Installation Guide

Module Slot Assignments

The specific slot locations for I/O modules and Supervisory modules in the chassis are as
follows:
XCM8810 switch
Slots 1, 2, 3, 4, 7, 8, 9, and 10 can accommodate only I/O modules.
-
Slot 5/A can accommodate only an Supervisory module.
-
Slot 6/B can accommodate an Supervisory module or I/O module
-
XCM8806 switch
Slots 1, 2, 5, and 6 can accommodate only I/O modules.
-
Slot 3/A can accommodate only an Supervisory module.
-
Slot 4/B can accommodate an Supervisory module or I/O module
-
The following slots can only operate an Supervisory module:
Slot 5/A in the XCM8810 chassis
Slot 3/A in the XCM8806 chassis
Supervisory modules reside in different slots depending on which switch you operate:
If you are using only one Supervisory module in the XCM8806 switch, install that
Supervisory module in slot 3. If you add a second Supervisory module to increase
reliability and throughput, install the second Supervisory module in slot 4.
If you are using only one Supervisory module in the XCM8810 switch, install that
Supervisory module in slot 5. If you add a second Supervisory module to increase
reliability and throughput, install the second Supervisory module in slot 6.

Distinguishing a Supervisory Module from an I/O Module

One quick way to distinguish an 8800 series Supervisory module from an I/O module is by
the color of the release latch on each injector/ejector handle. Orange injector/ejector release
Chapter 7. Install Modules and Establish Initial Management Access
| 61