8800 Series Chassis Switch Hardware Installation Guide
Do not connect a power supply to an electrical outlet when the
power supply is not installed in the chassis; doing so would
expose a hazardous energy and poses a potential shock and fire
hazard.
Do not put your hand into an open power supply bay when a
power supply is not present. Empty power supply bays require a
cover plate at all times.

Selecting Power Supply Cords

The following power cord requirements apply to cords used with the 700W PSU
XCM888PS1:
The power supply cord needs to be agency-certified for country of use, and rated at 10A
by in-country regulatory authority.
The power supply cord has to have an IEC 320 C13, 90-degree angle plug to connect to
the IEC320 C14 connector on the power supply.
The power cord requires an appropriately rated and approved wall plug applicable to the
country of installation.
For cords up to 6 feet (2 m) long, the wire size has to be 18 AWG (.75 mm
over 6 feet, the minimum wire size is 16 AWG (1.0 mm
WARNING!
Make sure that the source outlet is properly grounded according
to the country's local electrical requirements before plugging the
AC supply power cord into a PSU.
For specific product input power requirements refer to the data sheet of the product or PSU at
www.netgear.com
This equipment is not intended to be directly powered by power
Note:
distribution systems where phase-phase voltages exceed 240V AC
(2P+PE), such as those used in Norway, France, and other
countries. For these applications it is recommended that a
transformer be used to step down the voltage to < 240V AC from
phase-phase, or that you make a connection to a (P+N+PE) power
or to
Appendix B, Technical
2
).
Specifications.
Appendix A. Safety Information
2
) minimum;