14.3.2 Setting a serial port

Verify the setting of the serial port of this equipment and perform initial setting by using the [Serial Port]
dialogue.
[Operation procedure]
Open the [Serial Port] dialogue by performing the following menu operations.
[Menu] button → Service → Installation → System Configuration → Serial Port

14.3.2.1 [Diagnosis] lamp light colours

The [Diagnosis] lamp displays the diagnosis result as to whether the sentence of a sensor specified for
each serial port is received and the status of ISW/MTR/OPU.
Lit in red:
Data not received.
Lit in green:
Data is receiving.
Lit in orange: In diagnosis (before decision).
No colour:
Serial port is disabled.
14.3.2.2 Setting a serial port
In the [Serial Port] dialogue, allocate sensors to be connected to the serial port on RPU (central
processing unit) and the serial port on SLC.
[RPU] tab
[Setting a serial port on RPU]
Set each item as follows.
"Table A Sensors that can be selected by serial ports on RPU" shows selectable sensors.
However, the sensors that actually can be selected vary depending on the equipment setting.
For the sensor communication speed, refer to "Selectable baud rates".
Setting Item
GPS
1. Select the [RPU] tab.
2. Enable the serial port for GPS by selecting the [GPS]
3. Select a sensor to be connected to the serial port for
Gyro Compass
1. Select the [RPU] tab.
2. Enable the serial port for Gyro Compass by selecting
3. On the [Sensor] combo box, select a sensor to be
Section 14 Adjusting and Setting up Equipment (for Services) 14-16
Description of Setting
check box.
the GPS from the [Sensor] combo box. When not
selecting a sensor, set [ - ].
the [Gyro Compass] check box.
connected to the gyro compass serial port. When not
selecting a sensor, select 0.1.[-].
Setting Value
To enable: Select.
To disable: Clear.
Refer to Table A for
selectable sensors.
To enable: Select.
To disable: Clear.
Refer to Table A for
selectable sensors.