Symptom
Log is not displayed or the
values are not displayed
correctly.
Rudder angles are not
displayed.
Alternatively, the values are
not displayed correctly.
Wind direction/wind speed
(anemoscope/anemometer)
data is not displayed
Cause
The communication is not set
correctly.
The power supply for the log
equipment is not turned on.
The connection with the log
equipment is abnormal.
The internal wiring is faulty.
The processing unit (NDC-1678) is
faulty.
The communication is not set
correctly.
The power supply for the rudder
angle indicator is not turned on.
The connection with the rudder
angle indicator is abnormal.
The internal wiring is faulty.
The processing unit (NDC-1678) is
faulty.
The communication is not set
correctly.
The power supply for the
anemoscope/anemometer is not
turned on.
The connection with the
anemoscope/anemometer is
abnormal.
The internal wiring is faulty.
The processing unit (NDC-1678) is
faulty.
16-13
Action
Set the communication correctly.
Turn on the power supply for the log
equipment.
Check the connection with the log
equipment.
When log equipment is connected
to the terminal board circuit
(CQD-2322), check if the
corresponding LED blinks at signal
reception.
Make a request to the distributor for
repair.
Make a request to the distributor for
repair.
Set the communication correctly.
Turn on the power supply for the
rudder angle indicator.
Check the connection with the
rudder angle indicator.
When a rudder angle indicator is
connected to the terminal board
circuit (CQD-2322), check if the
LED of the corresponding port is lit
at data reception.
Make a request to the distributor for
repair.
Make a request to the distributor for
repair.
Set the communication correctly.
Turn on the power supply for the
anemoscope/anemometer.
Check the connection with the
anemoscope/anemometer.
When an anemoscope/anemometer
is connected to the terminal board
circuit (CQD-2322), check if the
LED of the corresponding port is lit
at data reception.
Make a request to the distributor for
repair.
Make a request to the distributor for
repair.