Gate Display]; Status] Display - JRC JMR-5410-4X Instruction Manual

Hide thumbs Also See for JMR-5410-4X:
Table of Contents

Advertisement

To cancel simulation
1
Click on the Standby/Transmit selector button to place the radar in the standby state.
The button indication changes to [Standby] to enter transmission preparation state.
2
Select [Off] from the [TT Simulator] combo box in the [TT Test] dialogue.
TT Simulator display turns off.
6.5.8.3

[Gate Display]

The gate displays an area monitoring a target using the TT function. This equipment allows the gate
size to change automatically according to target range and size. The gate size can be checked using
the following function.
1
Select the [Gate Display] checkbox.
When [Gate Display] is selected, the gate is displayed.
When [Gate Display] is cleared, the gate is not displayed.
2
Set the cursor mode to the AUTO mode.
3
Click on the target of tracking whose numerical value is to be displayed.
Numeric data for the specified target is displayed in the information monitoring window.
The numeric value for the target is displayed, and the gate is displayed in green around the
target tracking symbol.
Memo
The Target Tracking can display the gate of two targets simultaneously.
Tracked
target
symbol
6.5.8.4

[Status] display

The status of the TT function is displayed.
1
Check the display of [Status].
[Vector Constant]
[VD Level Mode (Manual)]
[VD Level (Manual)]
[Video Level (AUTO)]
[Gate Size]
[Tracking]
Section 6 Target Tracking and AIS
Echo
: Vector response
: Using quantization level on manual acquisition
: Quantization level on manual acquisition
: Quantization level on automatic acquisition
: Size of gate used for tracking
: Number of targets currently acquired
6-30
Vector
Gate (displayed in green)