6.5.2 Setting up the automatic acquisition/
activation zone (AZ)
Auto acquisition/activation zone has the shape of sector set up according to the angle and distance as
shown in the following figure.
AZ1
AZ2
Example of AUTO acquisition/activation zone (AZ)
AUTO acquisition/activation zone (AZ) is set up using the following three methods.
(1) Set by selecting [Alert] - [New Target Alarm].
(2) Use the cursor.
(3) Use the EBL/VRM dial.
6.5.2.1
Using [New Target Warning] dialogue box in the [Alert]
menu
[Operation procedure]
Open the target acquisition alarm setup screen by performing the following menu operations.
[Menu] button → Alert → New Target Alarm
1
To set up AZ1, select the [Use AZ1] check box. To set up AZ2, select the [Use AZ2]
check box.
2
To set up [Use AZ1], click on the [1] tab. To set up [Use AZ2], click on the [2] tab.
Their respective setting items are displayed.
3
Select [Start Angle], [End Angle], [Start Distance], and [End Distance] of AZ and enter
the information from the numeric value input keyboard.
Section 6 Target Tracking and AIS
End Angle
Start Angle
Start Distance
End Distance
6-20