Refer to
Detail of front rack spacer assembly for RealPresence Collaboration Server (RMX)
1500/2000/4000
● Using a shelf
Install the shelf, supplied by the rack manufacturer, in the rack.
Mount the Collaboration Server unit on the shelf.
Fasten the Collaboration Server unit to the rack with screws through the four holes in the
Collaboration Server front mounting brackets.
Connect the RealPresence Collaboration Server (RMX)
1500 to a Power Source
The following restrictions apply to the conductors and connectors that may be used to ground the unit when
rack mounted:
● When using bare conductors, they must be coated with an appropriate antioxidant compound before
crimp connections are made. Tinned, solder-plated or silver-plated connectors do not have to be
prepared in this manner.
● The same bolt assemblies should not secure multiple connectors.
Polycom, Inc.
for installation instructions.
Install the RealPresence Collaboration Server (RMX) 1500