To install RTM ISDN 2000 Card on RealPresence Collaboration Server (RMX) 2000
1 On the new RTM ISDN card, move the ejector levers to their fully open position.
2 Slide in the RTM ISDN card in the RealPresence Collaboration Server (RMX) 2000 slot.
An RTM ISDN card must connect directly to an MPMx/MPMRx card in the opposite-facing front slot.
3 Push the card into the slot until the ejector levers touch the front edge of the card cage.
4 Push the ejector levers to their fully closed position.
5 Tighten the captive screws on each side of the rear panel of the card, securing the RTM ISDN card
to the Collaboration Server.
Mount the RealPresence Collaboration Server (RMX)
2000 in a Rack
The RealPresence Collaboration Server (RMX) 2000 must be lifted into the rack by two people.
There are two methods for installing the RealPresence Collaboration Server (RMX) 2000 in a 19" rack
(which must be lifted by two people):
● Using rack rail runners on the rack