Polycom RealPresence RMX 1500 Getting Started Manual page 54

Collaboration server
Hide thumbs Also See for RealPresence RMX 1500:
Table of Contents

Advertisement

 RealPresence Collaboration Server 4000 with DC power supply
Switch on the ON/OFF switch on the rear panel, then turn ON each of the DC PEMs, the FAN
STATUS and PWR STATUS LEDs are light.
When the system is powered on, the configurations in the lan.cfg file are uploaded from the USB key
to the memory of Collaboration Server and applied during the power-up sequence.System power-up
sequence may take up to five minutes.
3 Wait for the upload process to complete by observing following LED status.
 Initially, all the READY/IN USE/ERROR LEDs on the RealPresence Collaboration Server (RMX)
1500 or ERR/RDY/ACT LEDs on the RealPresence Collaboration Server (RMX) 2000/4000
flicker and flash.
 Upload is completed when all the LEDs turn off and only the red ERROR/ERR LED on the CTNL
unit of the RealPresence Collaboration Server 2000/4000 remain ON.
 When the configuration of the Collaboration Server is completed including the Management and
IP Network Services, and if there are no System Errors, the STATUS LED on the front panel of
Collaboration Server turns green.
 On the MPMx/MPMRx card of the RealPresence Collaboration Server (RMX) 2000/4000, initially,
the ERR/RDY/ACT LEDs all flicker and flash, until only the RDY LED turns ON on the media card,
while the ERR LED on the CTNL unit is still ON.
Do not remove the USB Key from the RealPresence Collaboration Server until the connection with
the MCU is established and the Login screen of the RMX Web Client is displayed. For more details,
see
Connect to MCU
Polycom, Inc.
.
First Entry Power-up and Configuration
54

Advertisement

Table of Contents
loading