RealPresence Collaboration Server (RMX) 1500 Hardware Guide
Collaboration Server (RMX) 1500 Bolt Installation
Mounting the RealPresence Collaboration Server (RMX) 1500 on a Shelf
Observe the following procedure to mount the RealPresence Collaboration Server (RMX) 1500 on a shelf.
To mount the RealPresence Collaboration Server (RMX) 1500 on a shelf:
1 Install the shelf supplied by the rack manufacturer in the rack.
2 Mount the RMX on the shelf.
3 Fasten the RMX to the rack with screws through the four holes in the RMX's front mounting brackets.
Connecting the RealPresence Collaboration Server (RMX) 1500 to a
Power Source
The following restrictions apply to the conductors and connectors that may be used to ground the unit when
rack mounted:
● When using bare conductors, they must be coated with an appropriate antioxidant compound before
crimp connections are made. Tinned, solder-plated or silver-plated connectors do not have to be
prepared in this manner.
● The same bolt assemblies should not secure multiple connectors.