● Listed fastening hardware must be compatible with the materials being joined and must be preclude
loosening, deterioration and electrochemical corrosion of the hardware and joint materials.
To connect the RealPresence Collaboration Server (RMX) 1500 to AC power:
1 Make sure that the power (push) button is switched OFF on the RealPresence Collaboration Server
(RMX) 1500.
2 Insert the power cable into the power connector on the rear panel of the RealPresence
Collaboration Server (RMX) 1500.
Do not connect the green or green-yellow wire to the system single-point ground screw.
Only the AC Power cable supplied by Polycom should be used.
The size of the protective earthing conductor should be a minimum of 10 AWG.
The outlet intended for connecting the power cord must be protected with an external overcurrent
protection device either in building or in the rack with the rating not higher than 20Amp.
Do not use an extension cord with the cable.
Connect Cables to the RealPresence Collaboration
Server (RMX) 1500
Perform following steps to connect cables to RealPresence Collaboration Server (RMX) 1500.
To connect the cables to the RealPresence Collaboration Server (RMX) 1500:
● Connect the Media cable to LAN 2 port.
 Optional. If LAN Redundancy or Multiple Networks options are used, connect the LAN cable to
LAN 1.
For more information, see LAN Redundancy and Multiple Network Services in the
Collaboration Server (RMX) 1500/1800/2000/4000 Administrator's
● Connect the Network cables to:
 the MNG (Signaling) port
 the MNGB (Management Network) port.
Polycom, Inc.
Install the RealPresence Collaboration Server (RMX) 1500
RealPresence
Guide.
31