C2 Register Definition 30.6. EPDAT: C2 EPROM Data
Bit
7
Name
Type
Reset
0
C2 Address: 0xBF
Bit
Name
7:0 EPDAT[7:0] C2 EPROM Data Register.
This register is used to pass EPROM data during C2 EPROM operations.
C2 Register Definition 30.7. EPSTAT: C2 EPROM Status
Bit
7
Name WRLOCK
RDLOCK
Type
R
R
Reset
0
C2 Address: 0xB7
Bit
Name
7
WRLOCK
Write Lock Indicator.
Set to '1' if EPADDR currently points to a write-locked address.
6
RDLOCK
Read Lock Indicator.
Set to '1' if EPADDR currently points to a read-locked address.
5:1
Unused
Read = 00000b; Write = don't care.
0
ERROR
Error Indicator.
Set to '1' if last EPROM read or write operation failed due to a security restriction.
C8051T620/1/6/7 & C8051T320/1/2/3
6
5
4
EPDAT[7:0]
0
0
0
6
5
4
R
R
0
0
0
Rev. 1.2
3
2
R/W
0
0
Function
3
2
R
R
0
0
Function
1
0
0
0
1
0
ERROR
R
R
0
0
291
Need help?
Do you have a question about the C8051T620 and is the answer not in the manual?
Questions and answers