Handling And Storing The Productdelivery And Storage; Delivery; Applications; Pumped Liquids - Grundfos SP Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
3.
Handling and storing the
storage
3.1

Delivery

WARNING
Crushing of feet
Death or serious personal injury
-
Stack the pumps with the biggest at the bottom,
and do not stack above 1 m.
-
Use lifting equipment which is approved for the
weight of the product.
-
Wear personal protective equipment.
WARNING
Crushing of hands
Death or serious personal injury
-
Stack the pumps with the biggest at the bottom,
and do not stack above 1 m.
-
Use lifting equipment which is approved for the
weight of the product.
-
Wear personal protective equipment.
The pump must remain in the packing until it is
placed in vertical position during installation.
Handle the pump with care.
When the pump part and motor are supplied as separate units
(long pumps), fit the motor to the pump as described in section
7.1 Fitting the motor to the
pump.
The extra nameplate supplied with the pump must be
fixed at the installation site.
Do not expose the pump to unnecessary impact and shocks.
3.2
Storage
Storage temperature
Pump: -20 - +60 °C.
Motor: -20 - +70 °C.
The motors must be stored in a closed, dry and well ventilated
room.
If MMS motors are stored, the shaft must be turned
by hand at least once a month. If a motor has been
stored for more than one year before installation, the
rotating parts of the motor must be dismantled and
checked before use.
The pump must not be exposed to direct sunlight.
If the pump has been unpacked, it must be stored horizontally,
adequately supported, or vertically to prevent misalignment of the
pump. Make sure that the pump cannot roll or fall over.
During storage, the pump can be supported as shown in fig. 1.
Fig. 1
Pump position during storage
3.2.1 Frost protection
If the pump has to be stored after use, it must be stored on a
frost-free location, or the motor liquid must be frost-proof.

4. Applications

Grundfos SP submersible pumps are designed for a wide range
of water supply and liquid transfer applications, such as the
supply of fresh water to private homes or waterworks, water
supply in horticulture and agriculture, drawdown of groundwater
and pressure boosting, and various industrial jobs.
productDelivery and
The pump must be installed so that the suction interconnector is
completely submerged in the liquid. The pump can be installed
horizontally or vertically. See section

4.1 Pumped liquids

Clean, thin, non-explosive liquids without solid particles or fibres.
The maximum sand content of the water must not exceed
3
50/100/150
ppmg/m
. A larger sand content will reduce the life of
the pump and increase the risk of blockage.
Maximum content of sand
Pump type
SP 1A - SP 5A
SP 7 - SP 14
SP 17 - SP 60
SP 77 - SP 215
When pumping liquids with a density higher than
of
water
(998-1000
correspondingly higher outputs must be used.
When pumping liquids with a density higher than that
Caution
of water, motors with correspondingly higher outputs
must be used.
If liquids with a viscosity higher than that of water are to be
pumped, contact Grundfos.
The pump versions SP A N, SP A R,
are designed for liquids with higher aggressiveness than drinking
water.
The maximum liquid temperature appears from section
temperatures/cooling Liquid temperatures and motor

4.2 Sound pressure level

The sound pressure level has been measured in accordance with
the rules laid down in the EC machinery directive 2006/42/EC.
Sound pressure level of pumps
The values apply to pumps submerged in
regulating
valve.
Pump type
SP 1A
SP 2A
SP 3A
SP 5A
SP 7
SP 9
SP 11
SP 14
SP 17
SP 30
SP 46
SP 60
SP 77
SP 95
SP 125
SP 160
SP 215
Sound pressure level of motors
The sound pressure level of Grundfos MS and MMS motors is
lower than 70 dB(A).
Other motor makesbrands: See installation and operating
instructions for these motors.
5.3 Positional
requirements.
[ppm]
50
150
100
50
that
kg/m2), motors with
SP(E)
N,
SP(E)
R
and
SPE
5.5 Liquid
cooling).
water, without external
L
[dB(A)]
pA
less than 70
79
79
82
5