Activating Know-How Protection - Siemens SINAMICS S150 NEMA Operating Instructions Manual

Converter cabinet units
Hide thumbs Also See for SINAMICS S150 NEMA:
Table of Contents

Advertisement

Functions that can be executed optionally when know-how protection is active
The functions listed below can be executed for activated know-how protection provided
diagnostic functions were permitted when it was activated:
● Trace function
● Function generator
● Measuring functions
Setting parameters, which can only be read when know-how protection is active
The following setting parameters cannot be changed, but can be read, when know-how
protection is activated:
● Motor parameters (p0100, p0300, p0304, p0305, p0349)
● Data sets (p0120, p0130, p0140, p0150, p0170, p0180)
● Encoder type (p0400)
● Units (p0505, p0595)
● Open-loop control parameters (p0806, p0864, p0870)
● Speeds, torques (p1080, p1082, p1520, p1532)
● Reference quantities (p2000, p2001, p2002, p2003, p2005, p2006, p2007)
These parameters are shown in STARTER in the expert list with a gray background.
Note
List of the setting parameters, which can only be read when know-how protection is active
A list of the setting parameters, which can only be read when know-how protection is
activated, are provided in the List Manual.
The list has the designation "KHP_ACTIVE_READ".
AOP30 with activated know-how protection
When know-how protection is activated, the AOP30 operator panel does not show protected
parameters.
The setting parameters, which can only be read when know-how protection is active, are
displayed. An attempt to change such an adjustable parameter, will be rejected and an error
message displayed.
9.3.22.2

Activating know-how protection

Know-how protection can be activated via STARTER in the online mode.
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
Functions, monitoring and protective functions
9.3 Drive functions
567

Advertisement

Table of Contents
loading

Table of Contents