Link Object, Instance Number: F6 hex
Supported services
Class
Table 6- 52
No.
1
2
3
Table 6- 53
No.
1
2
3
4
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
• Get Attribute all
• Get Attribute single
Class Attribute
Service
Type
get
UINT16
get
UINT16
get
UINT16
Instance Attribute
Service
Type
Name
get
UINT32
Interface Speed
get
-
Interface Flags
get
ARRAY
Physical Address
get,
Struct of
Interface Counters Optional, required if the "Media Counters Attribute"
get_and
_clear
UINT32
In Octets
UINT32
In Ucast Packets
UINT32
In NUcast Packets Received non-Unicast packets
UINT32
In Discards
UINT32
In Errors
UINT32
In Unknown
Protos
UINT32
Out Octets
UINT32
Out Ucast Packets Sent Unicast packets
UINT32
Out NUcast
packets
UINT32
Out Discards
UINT32
Out Errors
Instance
Name
Revision
Max Instance
Num of Instances
Value/explanation
0: link down,
10: 10 Mbps,
100: 100 Mbps
Bit 1: Link-Status
Bit 2: Duplex Mode (0: half duplex, 1 duplex)
bit 3 ... 5: Automatic state identification
Bit 6: Reset required
Bit 7: Local hardware fault (0 = ok)
r8935: Ethernet MAC address
is implemented.
Received octets
Received Unicast packets
Incoming packets, not processed
Incoming packets with errors
Incoming packets with unknown protocol
Sent octets
Sent non-Unicast packets
Outgoing packets, not processed
Outgoing packets, with errors