Functions, monitoring and protective functions
9.4 Extended functions
9.4.7.10
Jog
Description
Parameter p2591 can be used to switch between "Incremental jog" and "Jog velocity".
Jog signals p2589 and p2590 are used to specify the travel distances p2587 and/or p2588
and the velocities p2585 and p2586. The traversing distances are only effective for a "1"
signal at p2591 (jog incremental). When p2591 = "0", the travel range start or the travel
range end is approached at the specified velocity.
An overview of the "Jog" function is show in function block diagram 3610.
Function diagram
FP 3610
Parameters
• p2585
• p2586
• p2587
• p2588
• p2589
• p2590
• p2591
9.4.7.11

Status signals

The status signals relevant to positioning mode are described below.
Follow-up mode active (r2683.0)
The "Follow-up mode active" status signal indicates that follow-up mode has been activated
(via binector input p2655 (follow-up mode) or via a fault). In this status, the position setpoint
follows the actual position value, i.e. position setpoint = actual position value.
690
EPOS - jog mode (r0108.4 = 1)
EPOS inching 1 setpoint velocity
EPOS inching 2 setpoint velocity
EPOS inching 1 travel distance
EPOS inching 2 travel distance
BI: EPOS jog 1 signal source
BI: EPOS jog 2 signal source
BI: EPOS jog incremental
Operating Instructions, 12/2018, A5E36652151A