Fault Correction - Beckhoff XTS Hygienic Operating Instructions Manual

Extended transport system
Table of Contents

Advertisement

Motor modules
12.1
Warning
12.1.1
ID
Message
0x4101
Module overtemperature
0x4103
Undervoltage control voltage 24 V control voltage lower than
0x4411
Undervoltage DC-Link
0x4412
Overvoltage DC-Link
0x4414
I2T Motor overload
Version: 1.0
The following tables describe a selection of errors that are displayed
either as "warning" or "error" messages. Depending on the applica-
tion, other causes may be responsible for the malfunction.
Changes from firmware version 15
ID
Up to firmware version 14
0x4101
Terminal-Overtemperature
0x8109
0x810A
0x8403
0x840C
Omitted after firmware version 14
0x840B
Peak module overall current
threshold exceeded
12.1.1
Error
Motor module temperature exceeds
65 °C, see: COE 9000:19...9000:1C
20.4 V
48 V power supply is lower than 20 V
although the movers are not yet en-
abled
48 V power supply is higher than 56 V
although the movers are not yet en-
abled
I2T utilization rate of the motor mod-
ule at over 80 %
eXtended Transport System

Fault correction

From firmware version 15
Module overtemperature
New from firmware version 15
Peak overall current threshold ex-
ceeded
Number of the cause
1
2
3
2
3
4
2
5
6
───
87