Beckhoff XTS Hygienic Operating Instructions Manual page 71

Extended transport system
Table of Contents

Advertisement

1
Remove rail on support
1
1
2
Version: 1.0
When all remaining movers have been mounted:
► Check all round that the air gap between the magnetic plates 1
of the movers and the modules 2 is symmetrical on both sides of
2
the system and is approximately 0.70 mm
► Check that the magnetic plates are positioned parallel to the
modules
► Loosen and remove screws 1
► Remove rail on support 2
2
► Remove guard plate 1 and set screw 2
► Fit the lock again
► Observe tightening torques:
Components
Screws, M4 x 45
eXtended Transport System
Mechanical installation
Tightening torque [Nm]
6
───