Tr (Transmission Failure Count); Ua (Unicasts Attempted Count); Firmware Commands; Ck (Configuration Crc) - Digi XTend vB DigiMesh User Manual

Radio frequency (rf) module
Table of Contents

Advertisement

AT commands

TR (Transmission Failure Count)

This value is volatile (the value does not persist in the device's memory after a power-up sequence).
Parameter range
N/A
Default
N/A

UA (Unicasts Attempted Count)

The number of unicast transmissions expecting an acknowledgment (when RR > 0).
This value is volatile (the value does not persist in the device's memory after a power-up sequence).
Parameter range
0 - 0xFFFF
Default
0

Firmware commands

The following AT commands are firmware commands.

CK (Configuration CRC)

Displays the cyclic redundancy check (CRC) of the current AT command configuration settings.
This command allows you to detect an unexpected configuration change on a device.
After a firmware update this command may return a different value.
Parameter range
N/A
Default
N/A

DD (Device Type Identifier)

Stores the Digi device type identifier value. Use this value to differentiate between multiple XBee
devices.
If you change DD,
default values is to explicitly set it to defaults.
Parameter range
0 - 0xFFFFFFFF
Default
0x80000
XTend vB DigiMesh RF Module User Guide
RE (Restore Defaults)
will not restore defaults. The only way to get DD back to
Firmware commands