Parameter range
(read-only): 0 - 0xFFFF
Default
Varies
Bytes returned
2

TP (Board Temperature)

The current module temperature in degrees Celsius in 8-bit two's compliment format. For example 0x1A =
26°C, and 0xF6 = -10°C.
Sample output
26 C when CF = 0
1A when CF = 1
26 when CF = 2
Binary command
0x38 (56 decimal)
Parameter range
(read-only) 0 - 0x7F
Default
N/A
Bytes returned
1

TR (Transmit Error Count)

Reads the number of RF packets where retries expire without receiving an ACK (when RR > 0).
This count increments whenever a MAC transmission attempt exhausts all MAC retries without ever
receiving a MAC acknowledgment message from the destination node. Once the number reaches 0xFFFF,
it does not count further events. To reset the counter to any 16-bit value, append a hexadecimal
parameter to the command.