• Program VU:
• PRG output range that allows adjustment at 0 dB: -5.3dBm --+23 dBm.
3.6.2.- Analog characteristics measurement on Monitor Module.
• Common Line Inputs: IS' s, CUE' s y PA. (Balanced by TRF)
• Input impedance: > 6K5 Ω .
• Nominal input level ( 0 dBuVU): 0 dBu.
• Maximum input level for nominal adjustment: +17 dBu.
• Adjustment range for 0 dBu VU: -8 dBu -- + 12 dBu.
• Variation range at VU for nominal input: No VU adjustment.
• Bandwidth: 20 Hz -- 18 Khz -1 dBu; -12 dB a 20 Khz.
• EXT and LINE line inputs: (Balanced by TRF)
• Input impedance: > 6K5 Ω .
• Nominal input level ( 0 dBu VU): 0 dBu.
• Maximum input level for nominal adjustment: +17 dBu.
• Adjustment range for 0 dBu VU: -10 dBu -- + 10 dBu.
• Variation range at VU for nominal input: No VU adjustment.
• Bandwidth: 20 Hz -- 20 Khz -1 dBu.
• Micro input: (Balanced by TRF)
• Input impedance: > 3 KΩ .
• Nominal input level ( 0 dBu VU): -60 dBu.
• Maximum input level for nominal adjustment: -41 dBu.
• Adjustment range for 0 dBu VU: -53 dBu -- - 69 dBu.
• Variation range at VU for nominal input: No VU adjustment.
• Bandwidth: 20 Hz -- 20 Khz -1.5 dBu.
• EIN ( G = 60 dB): -117 dBu.
• EIN ( G = 69 dB): -122 dBu.
• EXT output: (Balanced by TRF)
• Output impedance: < 150 Ω .
• Nominal output level: 0 dBu.
• Maximum output level: +17 dBu.
• Absolute noise: -63 dBu.