2.3.1.2 Micro connection
The microphones are normally supplied with suitable plugs for direct
connection to the CU. The connector wiring for special uses is given below:
1: Ground
2: Signal V+
3: Signal V-
2.3.1.3 Tape connection (LINE)
The cable to the tape-recorder must be connected normally, with the terminal to
the CU fitted with a 3 pin male XLR connector. The connector wiring is given
below, for both balanced and unbalanced line outputs.
Balanced line outputs:
1: Ground
2: Signal V+
3: Signal V-
Unbalanced line outputs:
1: Ground and Signal V-
2: Signal V+
3 : Ground and Signal V-