Installing The Anti-Siphon Fill Receptacle - Toro Multi Pro WM Operator's Manual

Turf sprayer
Table of Contents

Advertisement

Installing the Tank
Note:
The Multi-Pro WM turf sprayer requires a
4-post ROPS or cab installed onto the Workman
vehicle.
1.
Assemble the freshwater tank and mount onto
the support tube with the 2 bolts (5/16 x 2-1/4
inch) and 2 flange locknuts (5/16 inch) as shown
in
Figure
47.
Figure 47
1. Freshwater tank mount
2. Flange locknut (5/16 inch)
3. Support tube (freshwater
tank)
2.
Torque the bolts and nuts to 20 to 25 N∙m (175
to 225 in-lb).
g033573
4. Washer (5/16 inch)
5. Bolt (5/16 x 2-1/4 inch)
19
Installing the Anti-Siphon
Fill Receptacle
Parts needed for this procedure:
1
Fill receptacle assembly
1
Flange-head bolt (5/16 x 3/4 inch)
Procedure
Place the fill-receptacle assembly over the threaded
hole in the tank
(Figure
flange-head bolt (5/16 x 3/4 inch).
1. Fill-receptacle assembly
38
48) and secure it with a
Figure 48
2. Flange bolt (5/16 x 3/4
inch)
g208978