the end of cylinder barrel and on the rod end of
the lift cylinder
(Figure
Figure 98
1. Bed support
2. Cylinder barrel
Lowering the Tank Assembly
1.
When you are ready to lower the tank assembly,
remove the bed support from the cylinder and
insert it into the brackets on the back of the
ROPS panel.
Important:
Do not try to lower the tank
assembly with the bed safety support on the
cylinder.
2.
Retract the lift cylinders to carefully lower the
tank to the frame.
3.
Install the 2 hold down bolts and fasteners to
secure the tank assembly.
4.
Fold the boom extensions rearward to the
extended position.
5.
Use the boom-control switches to raise the
boom extensions to the
98).
g009164
3. Bed
position.
TRANSPORT
Lubrication
Greasing the Sprayer
System
Service Interval: Every 100 hours
Lubricate all bearings and bushings after every
100 hours or once a year, whichever occurs first.
Grease Type: No. 2 lithium grease
1.
Wipe the grease fitting clean so that foreign
matter cannot be forced into the bearing or
bushing.
2.
Pump grease into the bearing or bushing.
3.
Wipe off the excess grease.
Greasing the Sprayer Pump
Service Interval: Every 50 hours
Grease Type: Mobil XHP 461
1.
Locate the grease fittings on the sprayer pump.
Note:
The pump is located at the rear end of
the machine.
1. Sprayer pump
2.
Wipe the 2 remote grease fittings clean.
3.
Pump grease into each remote grease fitting.
4.
Wipe off the excess grease.
70
Figure 99
2. Grease fitting
g208179