Toro Multi Pro WM Operator's Manual page 84

Turf sprayer
Table of Contents

Advertisement

2.
Assemble the agitation bypass valve, gasket,
and agitation-valve manifold with a flange clamp
and tighten by hand
3.
Align a gasket between the flanges of the rate
control valve and the agitation-valve manifold
(Figure
125A).
Figure 125
1. Flange (rate control valve)
2. Flange (master-boom
valve)
3. Flange clamp
4. Gasket
4.
Assemble the rate control valve, gasket, and
agitation-valve manifold with a flange clamp and
tighten by hand
(Figure
5.
Align a gasket between the flanges of the
agitation-valve manifold and the master-boom
valve
(Figure
125A)
6.
Assemble the agitation-valve manifold, gasket,
and master-boom valve with a flange clamp and
tighten by hand
(Figure
7.
Assemble the outlet fitting onto the coupling
fitting at the at the bottom of the manifold for the
agitation valve
(Figure
8.
Secure the outlet fitting to the coupling fitting by
inserting a retainer into the socket of the outlet
fitting
(Figure
125B)
9.
Assemble the agitation valve to the valve mount
with the flanged-head bolt and flanged locknut
(Figure
124) that you removed in step
Removing the Agitation Manifold Valve (page
78)
and torque the nut and bolt to 10 to 12 N∙m
(90 to 110 in-lb).
10.
If you loosened the mounting hardware for the
master-boom valve, tighten the nut and bolt to
10 to 12 N∙m (90 to 110 in-lb).
(Figure
125).
5. Coupling (manifold-valve)
6. Socket (outlet fitting)
7. Retainer
125A)
125A)
125B)
3
of
Installing the Master Boom
Manifold Valve
1.
Align the flange of the master-boom-valve
manifold, a gasket, and the flange of the
master-boom bypass valve
g033605
1. Flange (agitation valve)
2. Flange
(bypass—master-boom
valve)
3. Manifold (master-boom
valve)
2.
Assemble the master-boom valve manifold,
gasket, and master-boom bypass valve with a
flange clamp tightened hand tight
3.
Align the flange of the master-boom-valve
manifold, a gasket, and the agitation-valve
manifold
4.
Assemble the master-boom-valve manifold,
gasket, and agitation-valve manifold with a
flange clamp and tighten by hand
5.
Align the socket of the 90° outlet fitting onto
the coupling fitting at the at the bottom of the
manifold for the master-boom valve
127).
84
(Figure
Figure 126
4. Flange clamp
5. Gasket
6. 3-pin connector (valve
actuator—master-boom
valve)
(Figure
126).
126).
g033590
(Figure
126).
(Figure
126)
(Figure

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi pro wm 41240

Table of Contents