MADISON 250
THE 12 VOLT SOCKET FOR
THE CELLULAR PHONE
RECHARGE DOES NOT
WORK
A) Disconnect the two-way con-
nector from the socket and con-
nect the tester (DC 20V)
- Tester terminal (+): blue cable
terminal (F.32)
- Tester terminal (-): black cable
terminal
• Position the change-over switch key
on "ON"
• Measured voltage must be 12 volts
- According to the specification :
replace the socket body
- Out of specification : continue
searching.
B) Check the continuity of the blue
cable (positive) (tester DC 20V)
- Tester terminal (+): blue cable
terminal (F.33)
- Tester terminal (-): earthed to frame
• Position the change-over switch key
on "ON"
• Measured voltage must be 12 Volts
- According to the specification :
black cable is broken. Repair
- Out of specification : blue cable is
broken. Repair (see electric
diagram).
LA PRISE 12 VOLT POUR
LA RECHARGE DU
PORTABLE NE MARCHE
PAS
A) Déconnecter le connecteur à
deux voies de la prise et
connecter le testeur (DC 20V).
- Borne (+) testeur: cosse câble
bleu (F. 32)
- Borne (-) testeur: cosse câble noir
• Positionner la clef du commutateur
sur "ON"
• La tension doit être de 12 volt.
- Conforme aux indications: changer
le corps de la prise
- Non conforme aux indications:
poursuivre la recherche.
B) Vérifier la continuité du câble
bleu (positif) (testeur DC 20V).
- Borne (+) testeur: cosse câble
bleu (F. 33)
- Borne (-) testeur: à masse châssis
• Positionner la clef du commutateur
sur "ON"
• La tension doit être de 12 volt.
- Conforme aux indications: câble
noir interrompu, réparer.
- Non conforme aux indications:
câble bleu interrompu, réparer
(voir schéma électrique).
43
02/00
TOMA 12 VOLT PARA
RECARGA CELULAR
NO FUNCIONA
A) Desconectar el conector de dos
vías de la toma y conectar el te-
ster (DC 20V).
- Terminal (+) tester: terminal cable
azul (F. 32)
- Terminal (-) tester: terminal cable
negro
• Situar la llave conmutador en "ON"
• La tensión resultante debe ser de:
12 volt.
- Valores como los especificados :
sustituir cuerpo toma
Valores diferentes a los especifi-
-
cados : continuar la búsqueda.
B) Controlar la continuidad del ca-
ble azul (positivo) (tester DC 20V).
- Terminal (+) tester: terminal cable
azul (F. 33)
- Terminal (-) tester: en masa chasís
• Situar la llave conmutador en "ON"
• La tensión resultante debe ser de:
12 volt.
- Valores como los especificados :
cable negro interrumpido, reparar.
Valores diferentes a los especifi-
-
cados: cable azul interrumpido,
reparar (ver esquema eléctrico).