Positioner; Process Controller - AUMA AUMATIC AC 01.2 Manual

Hide thumbs Also See for AUMATIC AC 01.2:
Table of Contents

Advertisement

Appendix
Table 44: Positioner
No.
Type
Parameter
Offset (hexadecimal) = 0x04BE
Offset (decimal) = 1214
Data length = 30 bytes
14-1
enum
Adaptive behaviour
14-2
U16
Dead time
14-3
U16
Dead band OPEN
14-4
U16
Dead band CLOSE
14-5
U16
Positioner hyst. OPEN
14-6
U16
Positioner hyst.
CLOSE
14-7
I32
Tolerance CLOSE
14-8
I32
Tolerance OPEN
14-9
U16
Permissible starts/h
14-10
U16
Outer dead band
14-11
enum
Limit positioner range
14-12
U16
Limit OPEN
14-13
U16
Limit CLOSE
Table 45: Process controller
No.
Type
Parameter
Offset (hexadecimal) = 0x04F3
Offset (decimal) = 1267
Data length = 26 bytes
67-1
enum
Setpoint source
67-2
enum
Beh. setpoint failure
67-3
enum
Inverse operation
67-4
U16
Internal setpoint 1
67-5
U16
Internal setpoint 2
67-6
U16
Proport. gain Kp
54
Access
Default
Setting value
R/W
0
0 : Off
1 : Adaptive I
R/W
5
Min = 2 [0.1 s]
Max = 600 [0.1 s]
R/W
5
Min = 0 [0.1 %]
Max = 100 [0.1 %]
R/W
5
Min = 0 [0.1 %]
Max = 100 [0.1 %]
R/W
5
Min = 0 [0.1 %]
Max = 50 [0.1 %]
R/W
5
Min = 0 [0.1 %]
Max = 50 [0.1 %]
R/W
0
Min = 0 [0.1 %]
Max = 50 [0.1 %]
R/W
1000
Min = 950 [0.1 %]
Max = 1000 [0.1 %]
R/W
1200
Min = 1
Min = 1800
R/W
10
Min = 1 [0.1 %]
Max = 100 [0.1 %]
R/W
0
0 : Function not active
1 : Function active
R/W
1000
Min = 0 [0.1 %]
Max = 1000 [0.1 %]
R/W
0
Min = 0 [0.1 %]
Max = 1000 [0.1 %]
Access
Default
Setting value
R/W
0
0 : I/O interface
1 : Fieldbus interface
2 : Internal setpoint
R/W
0
0 : Internal setpoint 1
1 : Internal setpoint 2
2 : Failure behaviour
R/W
0
0 : Function not active
1 : Function active
R/W
500
Min = 0 [0.1 %]
Max = 1000 [0.1 %]
R/W
500
Min = 0 [0.1 %]
Max = 1000 [0.1 %]
R/W
10
Min = 1 [0,1]
Max = 100 [0,1]
Actuator controls
AC 01.2/ACExC 01.2 Modbus RTU
Explanation
Setting the adaptive behaviour
of the positioner
Setting the dead time
Setting dead band OPEN (irrel-
evant for adaptive behaviour)
Setting dead band CLOSE (irrel-
evant for adaptive behaviour)
Hysteresis in direction OPEN
(for adaptive positioner only)
Hysteresis in direction CLOSE
(for adaptive positioner only)
Tolerance for the function
"Closing fully" for end position
CLOSED
Tolerance for the function
"Opening fully" for end position
OPEN
Permissible number of starts/h
(only in combination with Adapt-
ive behaviour = Adaptive II)
Setting the outer dead band (ir-
relevant for adaptive behaviour)
Function Limit positioner range
Limit OPEN
Limit CLOSE
Explanation
Setpoint source of process con-
troller
Behaviour on setpoint failure
Inverse operation
Internal setpoint 1 for process
controller
Internal setpoint 2 for process
controller
Proportional gain Kp