Hardware Article No.; Type Of Seating; Torque Switching - AUMA AUMATIC AC 01.2 Manual

Hide thumbs Also See for AUMATIC AC 01.2:
Table of Contents

Advertisement

Appendix
No.
Type
Parameter
6-4
S20
Logic (Bootloader)
6-5
S20
Fieldbus
6-6
S20
Fieldbus (Bootloader)
6-7
S20
MWG
6-8
S20
MWG (Bootloader)
Table 39: Hardware article no.
No.
Type
Parameter
Offset (hexadecimal) = 0x04B7
Offset (decimal) = 1207
Data length = 140 bytes
7-1
S20
ArtNo LC
7-2
S20
ArtNo logic
7-3
S20
ArtNo MCM
7-4
S20
ArtNo PSO
7-5
S20
ArtNo I/O interface
7-6
S20
ArtNo fieldbus
7-7
S20
ArtNo MWG
Table 40: Type of seating
No.
Type
Parameter
Offset (hexadecimal) = 0x04B9
Offset (decimal) = 1209
Data length = 4 bytes
9-1
enum
End position CLOSED
9-2
enum
End position OPEN
Table 41: Torque switching
No.
Type
Parameter
Offset (hexadecimal) = 0x04BA
Offset (decimal) = 1210
Data length = 12 bytes
10-1
enum
Torque by-pass
10-2
U16
Torque by-pass [s]
52
Access
Default
Setting value
R
0
R
0
R
0
R
0
R
0
Access
Default
Setting value
R
_ ARTNR
OSS _
R
_ ARTNR LO-
GIK _
R
_ ARTNR RE-
LAIS _
R
_ ART-
NR_OPT _
R
_ ARTNR IN-
TF _
R
_ ARTNR
PBD _
R
_ ARTNR
MWG _
Access
Default
Setting value
R/W
0
0 : Limit
1 : Torque
R/W
0
0 : Limit
1 : Torque
Access
Default
Setting value
R/W
1
0 : Function not active
1 : Function active
R/W
0
Min = 0 [0.1 s]
Max = 50 [0.1 s]
Actuator controls
AC 01.2/ACExC 01.2 Modbus RTU
Explanation
Logic firmware version (Boot-
loader)
Fieldbus firmware version
Fieldbus firmware version
(Bootloader)
MWG firmware version
MWG firmware version (Boot-
loader)
Explanation
Article number of 'Local controls'
electronics sub-assembly (A9)
Article number of 'Logic' electron-
ics sub-assembly (A2)
Article number of 'MCM' (Motor
Control and Monitoring / A52)
electronics sub-assembly
Article number of 'PSO' (Power
Supply Options / A52.1) electron-
ics sub-assembly
Article number of 'I/O interface'
electronics sub-assembly (A1.0)
Article number of 'Fieldbus'
electronics sub-assembly (A1.8)
Article number of 'MWG' elec-
tronics sub-assembly (B6)
Explanation
Type of seating in end position
CLOSED
Type of seating in end position
OPEN
Explanation
Enabling/disabling torque by-
pass. Torque by-pass' = function
active means that the torque
monitoring is suspended for
each start and this for the time
as defined in the field 'Time
torque by-pass'. Consequently,
unseating is possible without
torque fault tripping.
By-pass duration of torque
monitoring at actuator start

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aumatic acexc 01.2

Table of Contents