Sign In
Upload
Manuals
Brands
AUMA Manuals
Controller
SQEx 05.2
AUMA SQEx 05.2 Manuals
Manuals and User Guides for AUMA SQEx 05.2. We have
8
AUMA SQEx 05.2 manuals available for free PDF download: Operating Instructions Manual, Operation Instructions Manual, Manual
AUMA SQEx 05.2 Operation Instructions Manual (108 pages)
Part-turn actuators, Control unit - Electromechanical with actuator controls
Brand:
AUMA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
5
Basic Information on Safety
5
Range of Application
5
Warnings and Notes
6
References and Symbols
7
2 Identification
8
Name Plate
8
Short Description
12
3 Transport, Storage and Packaging
14
Transport
14
Storage
15
Packaging
16
4 Assembly
17
Mounting Position
17
Handwheel Fitting
17
Part-Turn Actuator to Valve: Mount
17
Output Drive for Coupling
18
4.3.1.1. Part-Turn Actuator (with Coupling): Mount to Valve
18
Mounting Positions of Local Controls
21
Mounting Positions: Modify
21
5 Electrical Connection
22
Basic Information
22
KP/KPH Electrical Connection
24
Terminal Compartment: Open
25
Cable Connection
26
Terminal Compartment: Close
27
KES Electrical Connection
28
Terminal Compartment: Open
29
Cable Connection
30
Terminal Compartment: Close
31
KT/KM Electrical Connection
32
Terminal Compartment: Open
33
Cable Connection
34
Terminal Compartment: Close
36
External Earth Connection
37
Accessories for Electrical Connection
38
Actuator Controls on Wall Bracket
38
Parking Frame
39
Operation
40
Manual Operation
40
Manual Operation: Engage
40
Manual Operation: Disengage
40
Motor Operation
40
Local Actuator Operation
40
Actuator Operation from Remote
41
Menu Navigation Via Push Buttons (for Settings and Indications)
42
Menu Layout and Navigation
43
User Level, Password
44
Password Entry
44
Password Change
45
Language in the Display
45
Language Change
45
Indications
47
Indications During Commissioning
47
Indications in the Display
47
Feedback Indications from Actuator and Valve
48
Status Indications According to AUMA Classification
50
Status Indications According to NAMUR Recommendation
51
Indication Lights of Local Controls
53
Mechanical Position Indication Via Indicator Mark
54
Signals (Output Signals)
55
Status Signals Via Output Contacts (Digital Outputs)
55
Assignment of Outputs
55
Coding the Outputs
55
Analogue Signals (Analogue Outputs)
55
Commissioning (Basic Settings)
56
End Stops in Part-Turn Actuator
56
End Stop CLOSED: Set
57
End Stop OPEN: Set
57
Type of Seating: Set
58
Switch Compartment: Open
59
Torque Switching: Set
60
Limit Switching: Set
61
End Position CLOSED (Black Section): Set
61
End Position OPEN (White Section): Set
61
Intermediate Positions: Set
62
Running Direction CLOSE (Black Section): Set
62
Running Direction OPEN (White Section): Set
63
Test Run
63
Direction of Rotation at Mechanical Position Indicator: Check
63
Limit Switching: Check
64
Reference Operation Position Feedback: Perform
64
Mechanical Position Indicator: Set
64
Switch Compartment: Close
65
Commissioning (Optional Equipment Settings)
66
EWG 01.1 Electronic Position Transmitter
66
Measuring Range: Set
67
Current Values : Adjust
67
LED End Position Signalling: Switch On/Off
68
Potentiometer
68
Potentiometer: Set
68
RWG Electronic Position Transmitter
69
Measuring Range: Set
69
Corrective Action
71
Faults During Commissioning
71
Fault Indications and Warning Indications
71
Fuses
75
Fuses Within the Actuator Controls
75
Fuse Replacement
76
Replace Fuses
76
Test/Replace Fuses
77
Motor Protection (Thermal Monitoring)
77
Servicing and Maintenance
79
Preventive Measures for Servicing and Safe Operation
79
Disconnection from the Mains
79
Disconnection from the Mains with KP/KPH and KES Electrical Connection
79
Disconnection from the Mains with KT/KM Electrical Connection
81
Maintenance
82
Disposal and Recycling
82
Technical Data
84
Technical Data Part-Turn Actuator
84
Technical Data Actuator Controls
87
Spare Parts
92
Part-Turn Actuators Sqex
92
Sqex 14.2/Sqrex 05.2
92
Sqrex 14.2 KT/KM
92
Actuator Controls Acexc 01.2 KP/KPH
94
Actuator Controls AUMATIC Acexc 01.2 KES
96
Actuator Controls Acexc 01.2 KT/KM
98
Certificates
100
Declaration of Incorporation and EU Declaration of Conformity
100
Index
103
Addresses
106
Advertisement
AUMA SQEx 05.2 Operating Instructions Manual (112 pages)
Part-turn actuators. Control unit: electronic (MWG) with actuator controls. ACExC 01.2 Non-Intrusive
Brand:
AUMA
| Category:
Controller
| Size: 3 MB
Table of Contents
Table of Contents
2
Safety Instructions
5
Prerequisites for the Safe Handling of the Product
5
Range of Application
6
Warnings and Notes
7
References and Symbols
7
Short Description
8
Name Plate
10
Transport and Storage
14
Transport
14
Storage
15
Assembly
17
Mounting Position
17
Handwheel Fitting
17
Mount Actuator to Valve
17
Overview on Coupling Variants
18
Mount Actuator (with Coupling)
18
Mounting Positions of Local Controls
21
Mounting Positions: Modify
21
Electrical Connection
22
Basic Information
22
Overview of AUMA Electrical Connections
24
KT/KM Electrical Connection
26
Terminal Compartment: Open
27
Cable Connection
28
Fieldbus Cables: Connect
30
Fieldbus Connection for Line Topology
30
Terminal Compartment: Close
32
KP/KPH Electrical Connection
33
Terminal Compartment: Open
34
Cable Connection
35
Fieldbus Cables: Connect
36
Terminal Compartment: Close
37
KES Electrical Connection
38
Terminal Compartment: Open
39
Cable Connection
40
Fieldbus Cables: Connect
41
Terminal Compartment: Close
42
External Earth Connection
42
Accessories for Electrical Connection
43
Actuator Controls on Wall Bracket
43
Parking Frame
44
Operation
45
Manual Operation
45
Manual Valve Operation
45
Motor Operation
45
Operating the Actuator from Local Controls
45
Actuator Operation from Remote
46
Menu Navigation Via Push Buttons (for Settings and Indications)
47
Menu Layout and Navigation
48
User Level, Password
49
Password Entry
49
Password Change
50
Timeout for Incorrect Password Entry
50
Language in the Display
51
Language Change
51
Indications
52
Indications During Commissioning
52
Indications in the Display
52
Feedback Signals from Actuator and Valve
53
Status Indications According to AUMA Classification
55
Status Indications According to NAMUR Recommendation
56
Indication Lights of Local Controls
58
Mechanical Position Indication (Self-Adjusting)
58
Mechanical Position Indication Via Indicator Mark (Not Self-Adjusting)
59
Signals (Output Signals)
60
Signals Via Modbus RTU
60
Status Signals Via Output Contacts (Digital Outputs)
60
Assignment of Outputs
60
Coding the Outputs
60
Analogue Signals (Analogue Outputs)
61
Commissioning (Basic Settings)
62
End Stops in Part-Turn Actuator
62
Set End Stop CLOSED
63
Set End Stop OPEN
63
Type of Seating: Set
64
Torque Switching: Set
65
Limit Switching: Set
67
Fieldbus Address (Slave Address): Set
68
Test Run
69
Direction of Rotation at Mechanical Position Indicator: Check
70
Limit Switching: Check
70
Commissioning (Settings in the Actuator)
72
Switch Compartment: Open/Close
73
Mechanical Position Indicator (Self-Adjusting)
73
Mechanical Position Indicator: Set
74
Gear Stage of the Reduction Gearing: Test/Set
74
Mechanical Position Indication Via Indicator Mark (Not Self-Adjusting)
75
Mechanical Position Indicator: Set
76
Gear Stage of the Reduction Gearing: Test/Set
76
Corrective Action
78
Faults During Commissioning
78
Fault Indications and Warning Indications
78
Fuses
82
Fuses Within the Actuator Controls
82
Fuse Replacement
83
Replace Fuses
83
Test/Replace Fuses
83
Motor Protection (Thermal Monitoring)
84
Servicing and Maintenance
85
Preventive Measures for Servicing and Safe Operation
85
Disconnection from the Mains
85
Disconnection from the Mains with KT/KM Electrical Connection
86
Disconnection from the Mains with KP/KPH and KES Electrical Connection
87
Maintenance
87
Disposal and Recycling
88
Technical Data
90
Technical Data Part-Turn Actuator
90
Technical Data Actuator Controls
92
Tightening Torques for Screws
98
Spare Parts
99
Part-Turn Actuators Sqex
99
Sqex 14.2/Sqrex 05.2
99
Sqrex 14.2 KT/KM
99
Actuator Controls Acexc 01.2 KT/KM
101
Actuator Controls Acexc 01.2 KP/KPH
103
Actuator Controls AUMATIC Acexc 01.2 KES
105
Index
109
AUMA SQEx 05.2 Operation Instructions Manual (92 pages)
Part-turn actuators, Control unit with actuator controls
Brand:
AUMA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
5
Basic Information on Safety
5
Range of Application
6
Warnings and Notes
6
References and Symbols
7
2 Identification
8
Name Plate
8
Short Description
12
3 Transport, Storage and Packaging
13
Transport
13
Storage
14
Packaging
15
4 Assembly
16
Mounting Position
16
Handwheel Fitting
16
Part-Turn Actuator to Valve: Mount
16
Output Drive for Coupling
17
4.3.1.1. Part-Turn Actuator (with Coupling): Mount to Valve
17
Mounting Positions of Local Controls
20
Mounting Positions: Modify
20
5 Electrical Connection
21
Basic Information
21
KES Electrical Connection
23
Terminal Compartment: Open
24
Cable Connection
25
Industrial Ethernet Cable: Connect
26
Terminal Compartment: Close
27
External Earth Connection
27
Accessories for Electrical Connection
28
Actuator Controls on Wall Bracket
28
Parking Frame
29
Operation
30
Manual Operation
30
Manual Operation: Engage
30
Manual Operation: Disengage
30
Motor Operation
30
Local Actuator Operation
30
Actuator Operation from Remote
31
Menu Navigation Via Push Buttons (for Settings and Indications)
32
Menu Layout and Navigation
33
User Level, Password
34
Password Entry
34
Password Change
35
Language in the Display
35
Language Change
35
Indications
37
Indications During Commissioning
37
Indications in the Display
37
Feedback Indications from Actuator and Valve
38
Status Indications According to AUMA Classification
40
Status Indications According to NAMUR Recommendation
41
Indication Lights of Local Controls
43
Mechanical Position Indication (Self-Adjusting)
43
Mechanical Position Indication Via Indicator Mark
44
Signals (Output Signals)
45
Status Signals Via Output Contacts (Digital Outputs)
45
Assignment of Outputs
45
Coding the Outputs
45
Analogue Signals (Analogue Outputs)
45
Commissioning (Basic Settings)
46
End Stops in Part-Turn Actuator
46
End Stop CLOSED: Set
47
End Stop OPEN: Set
47
Type of Seating: Set
48
Torque Switching: Set
49
Limit Switching: Set
51
Fieldbus Address (Slave Address), Baud Rate, Parity and Monitoring Time: Set
52
Modbus TCP/IP Gateway: Set
53
Test Run
53
Direction of Rotation at Mechanical Position Indicator: Check
53
Limit Switching: Check
54
Commissioning (Settings in the Actuator)
55
Switch Compartment: Open/Close
56
Mechanical Position Indicator (Self-Adjusting)
56
Mechanical Position Indicator: Set
57
Gear Stage of the Reduction Gearing: Test/Set
57
Mechanical Position Indication Via Indicator Mark (Not Self-Adjusting)
58
Mechanical Position Indicator: Set
59
Gear Stage of the Reduction Gearing: Test/Set
59
Corrective Action
61
Faults During Commissioning
61
Fault Indications and Warning Indications
61
Fuses
65
Fuses Within the Actuator Controls
65
Fuse Replacement
65
Replace Fuses
65
Test/Replace Fuses
66
Motor Protection (Thermal Monitoring)
66
Servicing and Maintenance
68
Preventive Measures for Servicing and Safe Operation
68
Disconnection from the Mains
68
Disconnection from the Mains with KP/KPH and KES Electrical Connection
68
Maintenance
69
Disposal and Recycling
70
Technical Data
71
Technical Data Part-Turn Actuator
71
Technical Data Actuator Controls
73
Spare Parts
79
Part-Turn Actuators Sqex
79
Sqex 14.2/Sqrex 05.2
79
Sqrex 14.2 KES
79
Actuator Controls Acexc 01.2 KES Modbus TCP/IP
81
Certificates
83
Declaration of Incorporation and EU Declaration of Conformity
83
Index
86
Addresses
89
Advertisement
AUMA SQEx 05.2 Operation Instructions Manual (80 pages)
Part-turn actuators with actuator controls
Brand:
AUMA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
5
Basic Information on Safety
5
Range of Application
5
Warnings and Notes
6
References and Symbols
7
2 Identification
8
Name Plate
8
Short Description
10
3 Transport, Storage and Packaging
11
Transport
11
Storage
11
Packaging
11
4 Assembly
12
Mounting Position
12
Handwheel Fitting
12
Actuator: Mount to Valve
12
Mounting Positions of Local Controls
14
Mounting Positions: Modify
15
5 Electrical Connection
16
Basic Information
16
Connecting Via Ex Plug/Socket Connector with Screw-Type Terminals (KP, KPH)
17
Terminal Compartment: Open
17
Cable Connection
18
Terminal Compartment: Close
19
Connecting Via Ex Plug/Socket Connector with Terminal Blocks (KES)
20
Terminal Compartment: Open
20
Cable Connection
21
Terminal Compartment: Close
22
Accessories for Electrical Connection
22
Controls Mounted to Wall Bracket
22
Parking Frame
23
Protection Cover
24
Earth Connection, External
24
6 Operation
25
Manual Operation
25
Manual Operation: Engage
25
Manual Operation: Disengage
25
Motor Operation
25
Local Operation
25
Actuator Operation from Remote
26
7 Indications
28
Indication Lights
28
Mechanical Position Indicator/Running Indication
28
8 Signals
30
Feedback Signals Via Output Contacts (Binary)
30
Feedback Signals (Analogue)
30
9 Commissioning (Basic Settings)
31
Heat-Up Time for Low Temperature Version
31
End Stops in Part-Turn Actuator
31
End Stop CLOSED: Set
32
End Stop OPEN: Set
33
Switch Compartment: Open
33
Torque Switching: Set
34
Limit Switching: Set
35
End Position CLOSED (Black Section): Set
35
End Position OPEN (White Section): Set
35
Intermediate Positions: Set
36
Running Direction CLOSE (Black Section): Set
36
Running Direction OPEN (White Section): Set
37
Test Run
37
Direction of Rotation: Check
37
Limit Switching: Check
38
PTC Tripping Device (Option): Test
38
Potentiometer Setting
38
Electronic Position Transmitter RWG: Set
39
Mechanical Position Indicator: Set
40
Switch Compartment: Close
40
Commissioning Controls Settings
42
Controls: Open
42
Type of Seating: Set
42
Push-To-Run Operation or Self-Retaining: Set
43
Running Indication (Blinker Transmitter): Activate/Deactivate
44
Torque Fault in Collective Fault Signal: Activate/Deactivate
44
Positioner
45
Input Ranges (Signal Type) for Setpoint and Actual Value
45
Behaviour on Loss of Signal (Actuator Reaction)
46
Adjustment in End Positions
47
Sensitivity Setting
49
Controls: Close
50
EMERGENCY Command (EMERGENCY - OPEN/EMERGENCY - CLOSE)
50
Corrective Action
52
Faults During Commissioning
52
Fuses
52
Fuses Within the Actuator Controls
52
Motor Protection (Thermal Monitoring)
53
Disconnection from the Mains
55
Preventive Measures for Servicing and Safe Operation
55
Servicing and Maintenance
55
Maintenance
56
Disposal and Recycling
57
Features and Functions of Actuator
58
Technical Data
58
Features and Functions of Actuator Controls
60
Service Conditions
61
Further Information
62
Part-Turn Actuator Sqex
63
Spare Parts
63
Sqex 14.2/Sqrex 05.2 Sqrex 14.2 with Ex Plug/Socket
63
Actuator Controls AUMA MATIC Amexc 01.1 Via Ex Plug/Socket Connector with Screw-Type
65
Actuator Controls AUMA MATIC Amexc 01.1 Via Ex Plug/Socket Connector with Terminal
67
Certificates
69
Declaration of Incorporation and EC Declaration of Conformity
69
ATEX Certificate
70
Index
76
Addresses
78
AUMA SQEx 05.2 Operation Instructions Manual (60 pages)
Part-turn actuators
Brand:
AUMA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
2
Safety Instructions
4
Prerequisites for the Safe Handling of the Product
4
Range of Application
5
Warnings and Notes
6
References and Symbols
6
Short Description
7
Name Plate
8
Transport and Storage
11
Transport
11
Storage
12
Assembly
13
Mounting Position
13
Fit Handwheel
13
Mount Actuator to Valve
13
Overview on Coupling Variants
14
Electrical Connection
17
Basic Information
17
Overview of AUMA Electrical Connections
18
KT/KM Electrical Connection
19
Open Terminal Compartment
20
Cable Connection
21
Close Terminal Compartment
23
KES Electrical Connection
24
Open Terminal Compartment
25
Cable Connection
26
Close Terminal Compartment
27
External Earth Connection
28
Accessories for Electrical Connection (Option)
28
Parking Frame
28
Operation
29
Manual Operation
29
Manual Valve Operation
29
Motor Operation
29
Indications (Option)
30
Mechanical Position Indication Via Indicator Mark
30
Signals (Output Signals)
31
Feedback Signals from Actuator
31
Commissioning (Basic Settings)
32
End Stops in Part-Turn Actuator
32
Set End Stop CLOSED
33
Set End Stop OPEN
33
Open Switch Compartment
33
Set Torque Switching
34
Set Limit Switching
35
Set End Position CLOSED (Black Section)
35
Set End Position OPEN (White Section)
36
Test Run
36
Check Direction of Rotation at Mechanical Position Indicator
36
Check Limit Switching
37
Set Mechanical Position Indicator
37
Close Switch Compartment
38
Commissioning (Optional Equipment Settings)
39
Potentiometer
39
Potentiometer Setting
39
RWG Electronic Position Transmitter
39
Set Measuring Range
40
EWG 01.1 Electronic Position Transmitter
40
Set Measuring Range
41
Adjust Current Values
42
Switch On/Off LED End Position Signalling
43
Set Intermediate Positions
43
Set Running Direction CLOSE (Black Section)
43
Set Running Direction OPEN (White Section)
44
Corrective Actions
45
Faults During Operation/Commissioning
45
Motor Protection (Thermal Monitoring)
46
Servicing and Maintenance
47
Preventive Measures for Servicing and Safe Operation
47
Disconnection from the Mains
47
Disconnection from the Mains with KT/KM Electrical Connection
48
Mains Disconnection with KES Electrical Connection
49
Maintenance
49
Disposal and Recycling
50
Technical Data
52
Technical Data Part-Turn Actuator
52
Tightening Torques for Screws
54
Spare Parts List
55
Part-Turn Actuators Sqex 05.2 - Sqex 14.2 KT/KM / Sqrex 05.2 - Sqrex 14.2 KT/KM
55
Index
57
AUMA SQEx 05.2 Manual (56 pages)
Part-turn actuators
Brand:
AUMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
2
Terminology
5
Abbreviations and Concepts
5
Application and Validity
7
Range of Application
7
Standards
7
Valid Device Types
7
Architecture, Configuration and Applications
8
Architecture (Actuator Sizing)
8
Configuration (Setting)/Version
9
Protection against Uncontrolled Operation (Self-Locking/Brake)
11
Operation Mode (Low/High Demand Mode)
11
Further Notes and Indications on Architecture
11
Applications (Environmental Conditions)
12
Safety Instrumented Systems and Safety Functions
13
Safety Instrumented System Including an Actuator
13
Safety Functions
13
Safe Inputs and Outputs
14
Redundant System Architecture
14
Examples of Applications
15
System Representation
17
Installation, Commissioning and Operation
18
Installation
18
Commissioning
20
Operation
20
Lifetime
21
Decommissioning
21
Indications on Display
22
Status Indications on SIL Functions
22
SIL Configuration Warning
23
Backlight
23
Signals
24
Signals Via SIL Module
24
SIL - Fault Signal Via the Standards Actuator Controls Display (for Troubleshooting Support)
24
Status Signals Via Output Contacts (Digital Outputs) of Standard Actuator Controls
25
Signals Via Fieldbus of Standard Actuator Controls
26
Tests and Maintenance
27
Safety Equipment: Check
27
Internal Actuator Monitoring with Control Via Standard Actuator Controls
27
Partial Valve Stroke Test (PVST): Execute
27
Proof Test (Verification of Safe Actuator Function)
29
Preliminary Test
30
Check Safe ESD Safety Operation Safe OPENING/CLOSING
30
Check SIL Fault Signal Actuator Monitoring
31
Check Safe ESD Reaction for Motor Protection (Thermal Fault)" Signals
31
Check Safe ESD Reaction to Limit Seating with Overload Protection
32
Check Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation)
33
Check Safe ESD Reaction to "Forced Torque Seating in End Position
35
Check Safe ESD Reaction for no Seating" (no Evaluation of Limit and Torque)
35
Check Safe STOP Function
37
Check Combination of Safe ESD and Safe STOP Function
37
Maintenance
38
Safety-Related Figures
39
Determination of the Safety-Related Figures
39
Specific Parameters for AC 01.2 Actuator Controls in SIL Version with Actuators of SQ
40
SIL Certificate
45
Checklists
46
Commissioning Checklist
46
Proof Test Checklists
46
Safe ESD Safety Operation (Safe OPENING/CLOSING) Irrespective of the Selected
46
SIL Fault Signal "Actuator Monitoring" Irrespective of the Selected Control Unit
46
Safe ESD Reaction for "Motor Protection (Thermal Fault)" Signals Irrespective of the
47
Safe ESD Reaction to "Limit Seating with Overload Protection
48
Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
48
Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
49
Safe ESD Reaction to Forced Torque Seating in End Position (Limit Evaluation) for Actu
50
Safe ESD Reaction to "No Seating" for Actuators with Electromechanical Control Unit
50
Safe STOP Function Irrespective of the Selected Control Unit
51
11.2.10. Combination of Safe ESD and Safe STOP - Irrespective of the Selected Control Unit
52
Index
55
AUMA SQEx 05.2 Manual (48 pages)
Part-turn actuators
Brand:
AUMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
2
Safety Instructions
4
Prerequisites for Safe Handling of the Product
4
Range of Application
5
Warnings and Notes
5
References and Symbols
6
Short Description
7
Name Tag
8
Transport and Storage
11
Transport
11
Storage
12
Assembly
13
Mounting Position
13
Handwheel Fitting
13
Mount Actuator to Valve
13
Overview on Coupling Variants
14
Electrical Connection
17
Basic Information
17
Electrical Connection KES-Ex D
18
Open Terminal Compartment
19
Cable Connection
20
Close Terminal Compartment
21
External Earth Connection
22
Operation
23
Manual Operation
23
Manual Valve Operation
23
Motor Operation
23
Indications (Option)
24
Mechanical Position Indication Via Indicator Mark
24
Signals (Output Signals)
25
Feedback Signals from Actuator
25
Commissioning (Basic Settings)
26
End Stops in Part-Turn Actuator
26
Set End Stop CLOSED
27
Set End Stop OPEN
27
Open Switch Compartment
27
Torque Switch Setting
28
Limit Switch Setting
29
Set End Position CLOSED (Black Section)
29
Set End Position OPEN (White Section)
30
Test Run
30
Check Direction of Rotation
30
Limit Switch Checking
31
Set Mechanical Position Indicator
31
Close Switch Compartment
32
Commissioning (Optional Equipment Settings)
33
Potentiometer
33
Potentiometer Setting
33
RWG Electronic Position Transmitter
33
Set Measuring Range
34
EWG 01.1 Electronic Position Transmitter
34
Set Measuring Range
35
Adjust Current Values
36
Switch On/Off LED End Position Signaling
37
Set Intermediate Positions
37
Set Running Direction CLOSE (Black Section)
38
Set Running Direction OPEN (White Section)
38
Corrective Actions
39
Faults During Operation/Commissioning
39
Motor Protection (Thermal Monitoring)
39
Servicing and Maintenance
40
Preventive Measures for Servicing and Safe Operation
40
Disconnection from the Mains
40
Disconnection from the Mains with KES-D Electrical Connection
41
Maintenance
41
Disposal and Recycling
42
Spare Parts List
44
Part-Turn Actuators Sqex 05.2 - 14.2 KES-Exd / Sqrex 05.2 - 14.2 KES-Exd
44
Index
46
AUMA SQEx 05.2 Manual (44 pages)
Brand:
AUMA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Terminology
4
Abbreviations and Concepts
4
2 Application and Validity
6
Range of Application
6
Standards
6
Valid Device Types
6
3 Architecture, Configuration and Applications
8
Architecture (Actuator Sizing)
8
Configuration (Setting)/Version
8
Further Notes and Indications on Architecture
10
Applications (Environmental Conditions)
10
4 Safety Instrumented System and Safety Functions
11
Safety Instrumented System Including an Actuator
11
Safety Functions
11
Safe Inputs and Outputs
12
Redundant System Architecture
13
Application Example
14
System Representation
14
Diagnostic Function by the Operator
14
Internal Diagnostics of Fail Safe Unit
15
5 Installation, Commissioning and Operation
16
Installation
16
Commissioning
18
Operation
18
Lifetime
18
Decommissioning
19
Disposal and Recycling
19
Indications
20
Signals
21
Signals Via FS Module
21
Status Signals Via Output Contacts (Digital Outputs) of Actuator Controls
21
Signals Via Fieldbus of Actuator Controls
21
Tests and Maintenance
22
Internal Actuator Monitoring with Control Via Actuator Controls
22
Safety Equipment: Check
22
Execute Partial Valve Stroke Test (PVST)
23
Proof Test (Verification of Safe Actuator Function)
24
Check ESD Operation (Safe OPENING/CLOSING)
24
Check ESD Operation (Safe OPENING/CLOSING) with Additional Tripping in Case of
25
Check Safe End Position Signal
26
Test Counter of FQM Diagnostic Operations Within the AC .2 Actuator Controls
27
Maintenance
27
Determination of the Figures
29
Safety-Related Figures
29
Specific Figures for Fail Safe Unit in SIL Version with Actuators of SQ .2 Series
29
Checklists
33
Commissioning Checklist
33
Proof Test Checklists
33
Safe ESD Safety Operation (Safe OPENING/CLOSING)
33
Review and Validation of the "Safe End Position Feedback Safety Function
34
FQM Diagnostic Operation Counter Checklist
36
SIL Declaration of Conformity (Example)
37
Index
43
Advertisement
Related Products
AUMA SQEx 14.2
AUMA SQEx 12.2
AUMA SQEx 07.2
AUMA SQEx 10.2
AUMA NORM SQR 05.2
AUMA SQ 05.2
AUMA SQR 07.2
AUMA SQR 10.2
AUMA SQR 07.2-F07
AUMA SQR 07.2-F10
AUMA Categories
Controller
Industrial Equipment
Control Unit
Control Systems
Valve Positioners
More AUMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL