5. Maintenance and conversion
PLEASE NOTE
With end plates CPV..-EPL-PG (part nos. 161 372
and 162 542) as well as with CPV..-EPR-PG (part
nos. 161 373 and 162 543), connection 12/14 is
sealed internally.
All available end plate combinations are listed in the
table below. Check that the end plates, which you wish
to fit, can in fact be combined (see end plate pairs
listed below).
End plate pairs with internal auxiliary pilot air for
individual tubing
CPV..-EPL-G
CPV..-EPL
CPV..-EPL-E
CPV... 9811d
CPV..-EPR
CPV..-EPR-G
CPV..-EPR-G
Description
– Connections only in
left-hand end plate
– Division into pressure zones
not permitted
– Not suitable for vacuum.
• Unused connections must
be sealed
– Connections only in
right-hand end plate
– Division into pressure
zones not permitted
– Not suitable for vacuum.
• Unused connections must
be sealed
– Connections in left and
right-hand end plates
– Division into pressure
zones permitted
– Valves to left of isolating
plate suitable for vacuum.
• Unused connections must
be sealed
5-15