2. Fitting
2.2.1 Fitting the pneumatic multiple connector plate
Make sure that the mounting surface can support the
weight of the pneumatic multiple connector plate and
the CPV valve terminal. Make sure also that there is
enough room to connect the power cables and the
pneumatic tubing.
Fitting the pneumatic multiple connector plate
(connection side)
In order to fit the pneumatic multiple connector plate in
the standard or extended design by the connection side
to a mounting surface, proceed as follows:
• Cut out a section of the mounting surface (dimen-
sions see Figs. 2/9 and 2/10).
• Drill four holes in the mounting surface. The position
and distances between these holes is shown in Figs.
2/9 and 2/10.
• Fasten the pneumatic multiple connector plate onto
the mounting surface with 4 screws of suitable
length.
Diameter of mounting holes and screw sizes
Pneumatic multiple connector plate
(standard version)
CPV10/14
4.5 mm
M4
CPV... 9811d
Pneumatic multiple connector plate
CPV18
5.5 mm
M5
(extended version)
CPV10/14/18
6.5 mm
M6
2-17