Festo CPV-ASI-8E8A-ZCE Series Brief Description

Valve terminal with as-interface

Advertisement

Quick Links

Compact performance
Brief description
CPV valve
terminal with
AS-Interface
Type
CPV-ASI-8E8A-Z-
CE
– English
8101727
2018-11b
[8101729]

Advertisement

loading

Summary of Contents for Festo CPV-ASI-8E8A-ZCE Series

  • Page 1 Compact performance Brief description CPV valve terminal with AS-Interface Type CPV-ASI-8E8A-Z- – English 8101727 2018-11b [8101729]...
  • Page 2 Translation of the original instructions Documentation on the product For all available product documentation è www.festo.com/pk Copyright: Festo SE & Co. KG Ruiter Straße 82 73734 Esslingen Germany Internet: http://www.festo.com E-Mail: service_international@festo.com Reproduction, distribution or sale of this document or communication of its contents to others without express authorization is prohibited.
  • Page 3 S Connect the earth connection on the left-hand end plate with low impedance (short cable with large cross-sectional area) to the earth potential. S Commission only a valve terminal which has been fitted and wired completely. Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 4 PWR LED Fault LED Meaning AS-Interface voltage applied, no fault No AS-Interface voltage on the bu flashes AS-Interface address not set (= 0) flashes Short circuit/overload at the inputs or address selector button actuated Bus communication failed (watchdog expired) Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 5: Installation Instructions

    Slave 1: IO code 7 Slave 2: IO code 7 Data bits: Inputs: Outputs: I/O = Bidirectional (B) The address mapping depends on the configuration of the master. Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 6 ID1 codes. Recommendation: For addressing use addressing device type ASI-PRG-ADR with adapter cable type KASI-ADR from Festo. Factory setting: slave 1: address #1, A-slave slave 2: address #1, B-slave The addressing device scans the existing slaves in the AS-Interface network.
  • Page 7 3.3 Address assignment of the valves When addressed, the valve terminal type CPV...-GE-ASI-8E8A-Z-M8-CE behaves like two individual slaves each with 4 inputs and 4 outputs (see section 3.1). Both valve terminal halves can be fitted with equipment as follows: Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 8 (e.g. code J, N, C, H, G, D, I, E) 7 blanking plate or separator plate (e.g. code L, S, T) 8 valve plates with 1 valve solenoid coil (e.g. code M, F, A) or blanking plate or separator plate Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 9 AS-Interface master then regards this slave as missing. The slave reports back as functioning once the short circuit has been eliminated. Inputs of the first slave Inputs of the second slave Pin allocation: 1: US+ 3: US– 4: Input Ix Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 10 S Only use power sources which guarantee reliable electrical isolation of the operating voltage as per EN 60204-1. By the use of PELV power units, protection against electric shock (protection against direct and indirect contact) is guaranteed in accordance with EN 60204-1. Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 11 3. Replace and screw tight the cable socket (max. 0.3 Nm). Seal open flat cable ends with the Festo cable cap type ASI-KK-FK or the cable sleeve type ASI-KT-FK. In this way you will avoid leakage currents and comply with protection class IP65.
  • Page 12 5 to 8 (slave 2) Instructions on removing the electric sub-base can be found in the pneumatics manual. The permitted valve combinations as well as the relevant DIP switch settings can be found in the table in section 3.3. Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 13: Technical Specifications

    The device is intended for use in industrial environments. Measures may need to be implemented in residential areas for interference suppression. Factory setting: slave 1 = address #1, A-slave (ID1 = 7 slave 2 = address #1, B-slave (ID1 = F Festo CPV-ASI-8E8A-Z-CE 2018-11b English...
  • Page 14 11 … 30 V OFF: -30 … 5 V – Sensor supply (US+/US−) ≥ AS-Interface Bus voltage - 2.5 V – Response delay typically 3 ms (at 24 V) for max. 30 ms, all solenoid coils switched simultaneously Festo CPV-ASI-8E8A-Z-CE 2018-11b English...